Pulsar PSDC 04124 Quick Start Manual

Psdc 12v/4a/4x1a power supply for up to 4 hd cameras - ptc/topic.

Advertisement

Quick Links

PSDC 04124
v.1.3
PSDC 12V/4A/4x1A
Power supply for up to 4 HD cameras - PTC/TOPIC.
EN**
Edition: 12 from 11.10.2017
Supersedes the edition: 11 from 24.04.2017

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSDC 04124 and is the answer not in the manual?

Questions and answers

Summary of Contents for Pulsar PSDC 04124

  • Page 1 PSDC 04124 v.1.3 PSDC 12V/4A/4x1A Power supply for up to 4 HD cameras - PTC/TOPIC. EN** Edition: 12 from 11.10.2017 Supersedes the edition: 11 from 24.04.2017...
  • Page 2 PSDC04124 Features: • • FPS technical output of fuse activation 4x1A/12V DC power output for powering 4 HD cameras indication • • protections: output voltage adjustment 12V÷15V DC • • 4 outputs protected with 1A fuses SCP short-circuit protection •...
  • Page 3 PSDC04124 1. Technical description. 1.1 General description. The PSDC04124 stabilized power supply is designed to supply HD cameras or other devices requiring stabilized voltage of 12V DC. The output voltage adjustment range is adjusted via a potentiometer within the range of 12V÷15V DC.
  • Page 4 PSDC04124 Fig. 2. The view of the PSU’s PCB. Table 2. Elements of the PSU (see fig. 3). Element no. Description L-N 230V AC power connectors, PE protection connector F fuse in the power supply circuit (230V AC) PSU module , potentiometer, output voltage adjustment within the range of 12V÷15V DC...
  • Page 5 PSDC04124 1.4. Specifications: - electrical specifications (tab.3) - mechanical specifications (tab.4) - operation safety (tab.5) - operating specifications (tab.6) Electrical specifications (tab. 3). Supply voltage 85 ÷ 264V AC Current consumption 0,6A@230VAC max. PSU power 60W max. Efficiency Output voltage...
  • Page 6 PSDC04124 Operating specifications (tab.6). Operating temperature -10ºC...+50ºC Storage temperature -25ºC...+60ºC Relative humidity 20%...90%, without condensation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insolation unacceptable Vibrations and impulse waves during transport PN-83/T-42106 2. Installation. 2.1 Requirements. The stabilized PSU is to be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a given country) for 230V/AC interference and low-voltage installations.
  • Page 7 PSDC04124 3.1. LED indication (fig. 4.). • LED1…LED4 green diodes indicate power at the outputs: LB4- AUX1…AUX4. In case of a power loss at the output (fuse activation), an appropriate diode goes out. (L1 for AUX1, L2 for AUX2 etc.) •...
  • Page 8 According to the EU WEE Directive – It is required not to dispose of electric or electronic waste as unsorted municipal waste and to collect such WEEE separately. Pulsar Siedlec 150, 32-744 Łapczyca, Poland Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 e-mail: biuro@pulsar.pl, sales@pulsar.pl http:// www.pulsar.pl, www.zasilacze.pl...

Table of Contents