Care And Maintenance; Troubleshooting - Caple ZEL900GM Instruction Manual

Black glass chimney hood
Hide thumbs Also See for ZEL900GM:
Table of Contents

Advertisement

CARE AND MAINTENANCE

IMPORTANT:
Before cleaning or maintenance please switch off the electricity supply and remove
the plug from the wall.
Regular cleaning
Use a soft damp cloth with lukewarm mildly soapy water or household cleaning
detergent. Never use metal pads, chemicals, abrasive material, abrasive cleaning
creams or stiff brushes to clean the appliance.
Cleaning the grease filter
Clean the filter every month to help minimise the risk of fire. The filter collects
grease, smoke and dust, therefore the filter is directly affecting the efficiency of the
cooker hood. If not cleaned, the grease residue (which is potentially flammable) will
saturate the filter. It can be easily cleaned with warm water and washing up liquid,
alternatively the filters can be cleaned in your dishwasher. Please ensure no other
items are washed with the filters, they must be washed separately to prevent food
becoming trapped in the gauze. Cleaning the grease filters in the dishwasher may
lead to discolouration, this is normal and is a not a fault with the product.
Replacing your charcoal filter
This only applies if you are using the hood in recirculation mode (not vented to
the outside). The charcoal filter traps your cooking odours and they need to be
replaced, this can vary depending on how frequently the cooker hood is used. We
recommend replacing them at least every 6 months.
This extractor uses CAP61CF charcoal filters. Filters can be purchased directly from
www.caple.co.uk.
Please keep this instruction manual for future reference
16
Instruction manual ZEL900 / ZEL900GM
REPLACING THE BULB
1. Switch the unit off and unplug the appliance.
2. Push out and unclip the old LED light.
3. Replace with the same type and rated bulb/lamp fixing.
LED lamp (max.1.5W).

TROUBLESHOOTING

Fault
Cause
The fan blade is jammed
The lights on, but
the fan does not
The motor is damaged
work
A blown fuse
The lights and fan
do not work
The power cord is loose
The fan blade is damaged
Serious vibration
The fan motor is not fixed
of the unit
tightly.
The unit is not hung
correctly on the bracket
The extraction
The filter requires
performance is
cleaning
not good
If the above table has not solved the problem please contact Caple Service by
phone on 0117 938 7420 or by email service@caple.co.uk
Instruction manual ZEL900 / ZEL900GM
Replacement the lampes
1. Switch the unit off and unplug the appliance.
2. Push out the Old LED lamp
3. Replace with the same type and rated lamp
Solution
Switch off the unit and contact
Caple Service. To be repaired by
qualified service personnel only.
5
Replace the fuse
Plug in to the power supply
again
Switch off the unit and contact
Caple Service. To be repaired by
qualified service personnel only
Switch off the unit and contact
Caple Service. To be repaired by
qualified service personnel only
Take down the unit and check
whether the bracket is in the
correct location.
Clean the grease filter as
directed in the 'Care and
maintenance' section. Replace
the charcoal filter (if in
recirculation mode)
Please keep this instruction manual for future reference