Description And Usage; Installation - Carrier KGAET0101ETK Installation Instructions Manual

Vent / exhaust pipe external trap kit

Advertisement

Single--- Stage Furnaces
340MAV
58MCA
340AAV
58MCB
345MAV
58MSA
350MAV
58MEB
350AAV
58MXA
351DAS
58MXB
353AAV
WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK
HAZARD
Failure to follow this warning could result in personal injury,
death and/or property damage.
Turn off gas and electrical supplies to unit and tag with
appropriate lockout before beginning any installation or
modification.
Follow all operating instructions on label
attached to furnace.
INTRODUCTION
WARNING
!
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal
injury or death.
Do not use this kit with variable- -speed furnaces.
Variable- -speed inducer pressure could force water out of
this trap and permit vent gas to leak into living space.
This instruction covers installation of the vent/exhaust pipe
external trap kit P/N KGAET101ETK in all fixed- -capacity,
multipoise condensing gas furnaces listed in Table 1.
VENT/EXHAUST PIPE
OPEN "STAND PIPE"
FOR A/C OR
HUMIDIFIER DRAIN
Furnace
Condensate
Trap
ALTERNATE VENT/EXHAUST
CONDENSATE TRAP KIT INSTALLATION
Fig. 1 - - Condensate Trap Plumbing Options for Vent Above
Floor
Table 1 – Gas Furnaces
PG9MAA
PG9MAB
321496-301
POSITION TEE AS SHOWN
322186-201
322187-201
308589-402
TO OPEN DRAIN
A99079
Two--- Stage Furnaces
58MTA
352MAV
58MTB
352AAV
58MEC
353BAV

DESCRIPTION AND USAGE

Use this vent/exhaust pipe external trap kit to reduce gurgle noise
concerns and/or to improve condensate draining in vent/exhaust
pipe.
This vent/exhaust pipe external trap kit contains the following
items:
Condensate trap
Tee vent fitting (2-in. (51 mm) PVC)
Bushing vent fitting (2 x 1-1/2-in. (51 x 38 mm) PVC)
Adapter fitting (1-1/2 (38 mm) male x 1-1/2 (38 mm)
female)

INSTALLATION

These instructions are written assuming kit is installed after
furnace and vent system have been installed and is operational.
Kit components and alternate methods of condensate plumbing
are shown in Fig. 1. If installing kit during initial installation,
install as shown in Fig. 2 through 9.
NOTE: This kit is designed for use with 2- -in. (51 mm) PVC
vent/exhaust pipe applications. Additional pipe diameters are
usable when field- -supplied PVC fittings are used with
condensate trap and bushing supplied in kit.
Drain pipe and fittings must conform to ANSI standards and
ASTM D1785 or D2846. CPVC or PVC cement and primer must
conform to ASTM D2564 or F493. See section for Special
Venting Requirements for installations in Canada for pipe,
fittings, cement, and primer material requirements for Canadian
installations.
WARNING
!
FIRE HAZARD
Failure to follow this warning could result in personal
injury, death or property damage.
Solvent cements are combustible. keep away from heat,
sparks and open flame. Use only in well- -ventilated areas.
Avoid breathing in vapor or allowing contact with skin or
eyes.
NOTE: Slope combustion- -air and vent pipes a minimum of 1/4- -
in. (6 mm) per linear ft. with no sags between hangers.
CAUTION
!
UNIT OPERATIONAL HAZARD
Failure to follow this caution may result in intermittent unit
operation.
This kit is intended to be located at the lowest point in the
vent system and no more than 24 in. (610 mm) horizontally
from where the vent exits the furnace to achieve proper
drainage.
2
PG9MXA
1
1
1
1