4.
Line-up holes in surface with holes in air compressor feet.
5.
Place the (4) washers (supplied)
between the floor and air compressor
feet. If needed, solid shims may be
placed between the washers and
floor to evenly distribute weight on all
four feet. See next figure.
6.
Place the (4) 3/8" lag screws through
the air compressor feet, washers,
shims, and into the anchors.
7.
Torque 3/8" lag screws to
7 - 10 ft. lbs.
Wiring Instructions
by qualified personnel such as a licensed electricians who is familiar with the
current national electrical code and any prevailing local electrical codes. Une
mauvaise connexion électrique de ce produit pourrait annuler la garantie et votre
assurance contre les incendies.
A qualified electrician needs to knows the following before wiring:
1.
The amperage rating of the electrical box should be adequate. Refer to the
Specification Chart for this information.
2.
The supply line should have the same electrical characteristics (voltage,
cycle, phase) as the motor. Refer to the motor nameplate, on side of motor,
for this information.
NOTE: The wiring must be the same as the motor nameplate voltage plus or
minus 10%. Refer to local codes for recommended wire sizes, correct wire size,
and maximum wire run; undersize wire causes high amp draw and overheating to
the motor.
compressor outlet tubes, heads, or cylinders.
GROUNDING INSTRUCTIONS
This product should be connected to a metallic, permanent wiring system, of an
equipment-grounding terminal or lead on the product.
Voltage and Circuit Protection
Refer to the specification chart for the voltage and minimum branch circuit
requirements.
1000003473
Improper electrical installation of this product may void its
warranty and your fire insurance. Have circuit wiring performed
Risk of Electrical Shock. Electrical wiring must be located
away from hot surfaces such as manifold assembly,
5/8" Washer
(supplied)
Shim Under
Washer
(not supplied)
10-ENG
3/8" Lag
Screw
(not supplied)
Surface Line
Concrete Anchor
(not supplied)

Advertisement