Summary of Contents for BJM Pumps FAHRENHEIT S-F Seires
Page 1
INSTALLATION, OPERATION & MAINTENANCE MANUAL ® FAHRENHEIT S-F& SX-F SERIES SIDE DISCHARGE Electric Submersible Pumps Single Phase 115V & 230V CAST IRON SINGLE PHASE S1500C-F 316 STAINLESS STEEL SINGLE PHASE SX750CSS-F SX1500CSS-F Read this manual carefully before installing, operating or servicing these pump models. Observe all safety information.
BJM Pumps® S-F & SX-F Series submersible pump. This manual also contains information to optimize performance and longevity of your BJM Pumps submersible pump. The F Series Fahrenheit® pumps are engineered to pump water based liquids up to 200°...
SAFETY Pump installations are seldom identical. Each installation and application can vary due to many different factors. It is the owner/service mechanics responsibility to repair, service, and test to ensure that the pump integrity is not compromised according to this manual.
The following are recommended installation practices/procedures for the pump. If there are questions in regards to your specific application, contact your local BJM Pumps distributor or BJM Pumps, LLC. PRE-INSTALLATION INSPECTION 1) Check the pump for damage that may have occurred during shipment.
For Storage Periods longer than 3 Years • Disassemble the pump and replace all of the O-rings, the Mechanical Seal, Seal Chamber Oil, and the Lip Seal. Repack the Bearings. • Remove the air check screw on the motor housing. Using an air compressor, pressurize the motor chamber to 13 psi and check for leaks using a spray bottle.
Do not lift the pump by the power cable or discharge hose/piping. Proper lifting equipment (rope/chain) must be used. POSITIONING THE PUMP BJM Pumps, S-F & SX-F Series pumps are designed to operate fully submerged. Data sheets can be obtained online at www.bjmpumps.com or by calling BJM Pumps, LLC at 860-399-5937.
PUMP ROTATION If wired properly to the control, the single phase BJM Pumps S-F and SX-F Series pump should operate with the correct pumping rotation. Verification is recommended prior to installing into the sump basin. Two ways to check the correct pump rotation: 1.
Damage to the pump or personal injury may result from alterations. The BJM Pumps, S-F and SX-F series pumps require a special control that contains the starting components, thermal sensor and Seal Minder connections. These pumps...
Use with approved motor control that matches motor input in full load amperes. “UTILLISER UN DÉMARREAR APPROUVÉ CONVENANT AU COURANT Á PLEINE CHARGE DU MOTEUR.” BJM Pumps has been evaluated for use with water or water based solutions. Please contact the manufacturer for additional information.
Page 11
Figure 1 SX750F-115 control Figure 2 SX750F-230, S1500F-230 and SX1500F-230 control...
OPTIONAL FLOAT CONNECTION BJM Pumps utilizes a control for all of the single phase “F” series pumps. The wiring diagram included in this manual (and with the control) should be followed to properly connect the pump power and sensor leads to the control, and the power supply to the control.
The design of the “F” series high temperature pump models is unique and requires specific knowledge to perform the proper assembly. BJM Pumps recommends that all electrical service work be performed at the factory, or by a factory trained and certified repair technician, to insure that the materials and assembly methods meet BJM standards.
Page 14
12) Assemble the pump. STATOR REPLACEMENT OR ELECTRICAL REPAIR The BJM Pumps “F” Series designed pumps utilize unique construction methods and materials. The inner connection of all wiring requires use of a BJM wire connection kit. Included in this kit are specific instructions on how a qualified factory trained and certified repair technician can perform this work properly.
The cable is designed for a high temperature environment. The proper replacement part can be found parts list found in this manual. BJM Pumps, can supply a control with the Seal Minder and Thermal sensor switch option. BJM Pumps requires the Seal Minder and...
BJM Pumps, LLC’s liability for any breach of this warranty shall be limited solely to replacement or repair, at the sole option of BJM Pumps, LLC, of any part or parts of the Product found to be defective during the warranty period, provided the Product is properly installed and is being used as originally intended.
START-UP REPORT FORM This form is designed to record the initial installation, and to serve as a guide for troubleshooting at a later date (if needed). BJM Pumps, LLC 123 Spencer Plain Road Old Saybrook, CT. 06475 Pump Owner’s Name...
Page 23
START-UP REPORT FORM Are guide rails vertical? Is base elbow installed level? Liquid level controls: Model Is control installed away from turbulence? Float Operation Check Tip lowest float (stop float), all pumps should remain off. Tip second float (and stop float), one pump comes on. Tip third float (and stop float), both pumps on (alarm on simplex).
Page 24
START-UP REPORT FORM L1-L2 L2-L3 L3-L1 Amperage load connection, pump on FINAL CHECK Is pump secured properly? Was pump checked for leaks? Do check valves operate properly? Flow: Do pumps appear to operate at proper rate? Noise level: Acceptable Unacceptable Comments: Installed by: Company:...
Need help?
Do you have a question about the FAHRENHEIT S-F Seires and is the answer not in the manual?
Questions and answers