Page 1
The first half of this manual covers the PUMP END (also called wet end) and general pump operation. The second half of this manual covers the XP-SK/XP-SKX/XP-JX Series motor. *** See the EIM ELECTRIC CO., LTD Instruction Manual for Installation, Operation &...
This Installation, Operation and Maintenance manual located in the front half of this manual only covers the pump end (wet end) of the XP-JX Series pumps. Refer to EIM ELECTRIC CO., LTD Instruction Manual located in the second half of this manual for Installation, Operation and Maintenance for the Explosion Proof Submersible Motors (EMQY Series;...
INSPECTION Review all safety information before servicing pump. The following are recommended installation practices/procedures for the pump. If there are questions in regards to your specific application, contact your local BJM Pumps distributor or BJM Pumps, LLC.
Give it to the owner or affix it to the control panel when finished with the installation. If anything appears to be abnormal, contact your BJM Pumps distributor or BJM Pumps, LLC. If damaged, the pump may need to be repaired before use. Do not install or use the pump until appropriate action has been taken.
Rotate the impeller shaft by hand prior to startup. POSITIONING THE PUMP BJM Pumps, J & JX Series pumps are designed to operate fully or partially submerged. Do not run the pump dry. Refer to data sheet for minimum submersion depth for your particular model.
WIRING INSTRUCTIONS Electrical wiring and protection must be in accordance with the National Electrical Code per NEC articles 500 through 503 for installation in Class I, Division 1, Group C & D Hazardous Locations, and any other applicable state and local electrical requirements. For motor specifications, motor technical data, design features, power supply, electrical wiring, operation, inspecting &...
2. By looking from the top of the pump. Since the impeller cannot be seen, the best way to check the rotation is to check the kick back motion of the pump when the pump just starts. The kick back motion of the pump should be counter clockwise as shown in the picture below.
STOPPING To stop the pump (manual and automatic mode) turn off the breaker, or turn the electrical power source off (generator). TROUBLE SHOOTING Disconnect the electrical power source to the pump BEFORE attempting any type of trouble shooting, service or repair. PUMP WILL NOT RUN Refer to EIM ELECTRIC CO., LTD Instruction Manual for Installation, Operation and Maintenance for the Explosion Proof Submersible Motors (EMQY Series;...
Cut or cracked power cords must be replaced. (Never operate a pump with a cut, cracked or damaged power cord.) Maintenance should always be done when taking a pump out of service before storage. The impeller to suction cover clearance should be adjusted to between 0.01” to 0.02”...
The sensor cable with Seal Minder and thermal sensor switch connections is standard on all XP-JX Series pumps. The proper replacement part can be found parts list found in this manual. BJM Pumps, can supply a control with the Seal Minder and Thermal sensor switch option. Separate stand alone Seal Minder alarm panels are also available.
BJM Pumps,LLC’s liability for any breach of this warranty shall be limited solely to replacement or repair, at the sole option of BJM Pumps,LLC, of any part or parts of the Product found to be defective during the warranty period, provided the Product is properly installed and is being used as originally intended. Any breach of this warranty must be reported to BJM Pumps,LLC or BJM Pumps,LLC’s authorized service representative within...
START-UP REPORT FORM This form is designed to record the initial installation, and to serve as a guide for troubleshooting at a later date (if needed). BJM Pumps, LLC 123 Spencer Plain Road Old Saybrook, CT. 06475 Pump Owner’s Name...
Page 21
START-UP REPORT FORM Are guide rails vertical? Is base elbow installed level? Liquid level controls: Model Is control installed away from turbulence? Float Operation Check Tip lowest float (stop float), all pumps should remain off. Tip second float (and stop float), one pump comes on. Tip third float (and stop float), both pumps on (alarm on simplex).
Page 22
START-UP REPORT FORM L1-L2 L2-L3 L3-L1 Amperage load connection, pump on FINAL CHECK Is pump secured properly? Was pump checked for leaks? Do check valves operate properly? Flow: Do pumps appear to operate at proper rate? Noise level: Acceptable Unacceptable Comments: Installed by: Company:...