INSTALLATION, OPERATION & MAINTENANCE MANUAL ® FAHRENHEIT SK-F & SKX-F SERIES SHREDDER PUMPS Electric Submersible Pumps Single Phase 208V & 230V CAST IRON SINGLE PHASE SK1500C-F 316 STAINLESS STEEL SINGLE PHASE SKX750CSS-F SKX1500CSS-F Read this manual carefully before installing, operating or servicing these pump models. Observe all safety information.
INTRODUCTION This Installation, Operation and Maintenance manual provides important information on safety and the proper inspection, disassembly, assembly and testing of the BJM Pumps® SK- F & SKX-F Series submersible pump. This manual also contains information to optimize performance and longevity of your BJM Pumps® submersible pump. The F-Series Fahrenheit®...
SAFETY Pump installations are seldom identical. Each installation and application can vary due to many different factors. It is the owner/service mechanics responsibility to repair, service, and test to ensure that the pump integrity is not compromised according to this manual.
Give it to the owner or affix it to the control panel when finished with the installation. If anything appears to be abnormal, contact your BJM Pumps® distributor or Industrial Flow Solutions Operating, LLC. If damaged, the pump may need to be repaired before use.
SK-F & SKX-F Series pumps have been evaluated for use with water or water based solutions with some solids. Please contact the manufacturer for additional information. The BJM Pumps® Shredder Pumps (7.5 HP and larger) are designed to handle unscreened sewage.
POSITIONING THE PUMP BJM Pumps® SK-F & SKX-F Series pumps are designed to operate fully submerged. Data sheets can be obtained online at www.flowsolutions.com or by calling Industrial Flow Solutions Operating, LLC at 860-399-5937. • Do not run pump dry.
PUMP ROTATION If wired properly to the control, the single phase BJM Pumps® SK-F and SKX-F Series pump should operate with the correct pumping rotation. Verification is recommended prior to installing into the sump basin. Two ways to check the correct pump rotation: 1.
Damage to the pump or personal injury may result from alterations. The BJM Pumps® SK-F and SKX-F series pumps require a special control that contains the starting components, thermal sensor and Seal Minder® connections.
Use with approved motor control that matches motor input in full load amperes. “UTILLISER UN DÉMARREAR APPROUVÉ CONVENANT AU COURANT Á PLEINE CHARGE DU MOTEUR.” BJM Pumps has been evaluated for use with water or water based solutions. Please contact the manufacturer for additional information.
Page 11
Figure 1 SKX750F-115 control Figure 2 SKX750F-230, SK1500-230 and SKX1500-230 control...
OPTIONAL FLOAT CONNECTION BJM Pumps® utilizes a control for all of the single phase “F” series pumps. The wiring diagram included in this manual (and with the control) should be followed to properly connect the pump power and sensor leads to the control, and the power supply to the control.
Pumps® recommends that all electrical service work be performed at the factory or by a factory trained and certified repair technician to insure that the materials and assembly methods meet BJM Pumps® standards. MAINTAINING YOUR PUMP • Pump should be disconnected from the electric power supply before proceeding to do any service or maintenance.
The BJM Pumps® “F” Series designed pumps utilize unique construction methods and materials. The interconnection of all wiring requires the use of a BJM Pumps® wire connection kit. Included in this kit are specific instructions on how a qualified factory trained and certified repair technician can perform this work properly.
SK-F SERIES PARTS LIST Pump Model SK1500CF Pos. No. Part Description Item # 01-2 Stand Only 202858 Suction Cover, Hi-Chrome 202046 Impeller, Heat Treated DI* 204565 Pump Housing 203008 Oil Chamber Cover 202213 08-1 O-Ring (Kit Only) Lip Seal FKM 202232 Mechanical Seal FKM 204240...
SKX-F SERIES PARTS LIST Pump Model SKX750CSSF SKX1500CSSF Pos. No. Part Description Part # Part # 01-2 Stand Only 201988 201995 Suction Cover, Hi-Chrome Impeller 202951 204628** Pump Housing 202176 202172 07-1 O-Ring (Kit Only) Oil Chamber Cover 202214 202214 08-1 O-Ring (Kit Only) Lip Seal FKM...
The cable is designed for a high temperature environment. The proper replacement part can be found parts list found in this manual. BJM Pumps, can supply a control with the Seal Minder and Thermal sensor switch option. BJM Pumps requires the Seal Minder and...
BJM Pumps, LLC’s liability for any breach of this warranty shall be limited solely to replacement or repair, at the sole option of BJM Pumps, LLC, of any part or parts of the Product found to be defective during the warranty period, provided the Product is properly installed and is being used as originally intended. Any breach of this warranty must be reported to BJM Pumps, LLC or BJM Pumps, LLC’s authorized service...
START-UP REPORT FORM This form is designed to record the initial installation, and to serve as a guide for troubleshooting at a later date (if needed). Industrial Flow Solutions Operating, LLC 104 John W Murphy Drive New Haven, CT 06513, USA Pump Owner’s Name Location of Installation Date of Installation:...
Page 23
START-UP REPORT FORM Are guide rails vertical? Is base elbow installed level? Liquid level controls: Model Is control installed away from turbulence? Float Operation Check Tip lowest float (stop float), all pumps should remain off. Tip second float (and stop float), one pump comes on. Tip third float (and stop float), both pumps on (alarm on simplex).
Page 24
START-UP REPORT FORM L1-L2 L2-L3 L3-L1 Amperage load connection, pump on FINAL CHECK Is pump secured properly? Was pump checked for leaks? Do check valves operate properly? Flow: Do pumps appear to operate at proper rate? Noise level: Acceptable Unacceptable Comments: Installed by: Company:...
INTRODUCTION This Installation, Operation and Maintenance manual provides important information on safety and the proper inspection, disassembly, assembly and testing of the BJM Pumps® SK- F & SKX-F Series submersible pump. This manual also contains information to optimize performance and longevity of your BJM Pumps® submersible pump. The F-Series Fahrenheit®...
Hazards or unsafe practices which COULD result in personal injury or product or property damage. These instructions describe the procedure required and the possible damage which could result from failure to follow the procedure. SAFETY Pump installations are seldom identical. Each installation and application can vary due to many different factors.
Give it to the owner or affix it to the control panel when finished with the installation. If anything appears to be abnormal, contact your BJM Pumps® distributor or Industrial Flow Solutions Operating, LLC. If damaged, the pump may need to be repaired before use.
Page 32
• Remove the air check screw on the motor housing. Using an air compressor, pressurize the motor chamber to 13 psi and check for leaks using a spray bottle. Repeat this procedure to check the seal chamber for leaks. • Inspect the power cable for any damage. For Storage Periods longer than 3 Years •...
SK-F & SKX-F Series pumps have been evaluated for use with water or water based solutions with some solids. Please contact the manufacturer for additional information. The BJM Pumps Shredder Pumps (7.5 HP and larger) are designed to handle unscreened sewage.
Do not lift the pump by the power cable or discharge hose/piping. Proper lifting equipment (rope/chain) must be used. POSITIONING THE PUMP BJM Pumps® SK-F & SKX-F Series pumps are designed to operate fully submerged. Data sheets can be obtained online at www.flowsolutions.com or by calling Industrial Flow Solutions Operating, LLC at 860-399-5937.
PUMP ROTATION Two ways to check the correct pump rotation: 1. By looking at the impeller; the rotation of the impeller should be counter clockwise as shown in the picture below. 2. By looking from the top of the pump. Since the impeller cannot be seen, the best way to check the rotation is to check the kick back motion of the pump when the pump just starts.
PUMP OPERATION This pump is designed to handle dirty water that contains some solids. It is not designed to pump volatile or flammable liquids. Do not attempt to pump any liquids which may damage the pump or endanger personnel as a result of pump failure.
STOPPING To stop the pump (manual and automatic mode), unplug it from the power source, turn off the breaker, or turn the power source off (generator). Typical 3 phase manual control 1 TYPICAL AUTOMATIC WASTEWATERING INSTALLATION NOTE: Maximum recommended starts should not exceed 10 times per hour.
Use with approved motor control that matches motor input in full load amperes. “UTILLISER UN DÉMARREAR APPROUVÉ CONVENANT AU COURANT Á PLEINE CHARGE DU MOTEUR.” BJM Pumps has been evaluated for use with water or water based solutions. Please contact the manufacturer for additional information.
THREE PHASE WIRING INSTRUCTIONS FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE HANDLING. “Risk of electrical shock” Do not remove power supply cord and strain relief or connect conduit directly to the pump. Installation and checking of electrical circuits and hardware should be performed by a qualified licensed electrician.
DO NOT PLACE HANDS IN PUMP SUCTION WHILE CHECKING MOTOR ROTATION. TO DO SO WILL CAUSE SERVER PERSONAL INJURY. Three phase pumps have integral motor overload protection. It is recommended that all three phase pumps using a motor starting device also incorporate motor overload protection.
Pump should be disconnected from the electric power supply before proceeding to do any service or maintenance. To service or repair your pump, please contact your local BJM Pumps® distributor. Service should only be performed by a qualified electrician. The design of the “F”...
Page 42
The BJM Pumps® “F” Series designed pumps utilize unique construction methods and materials. The interconnection of all wiring requires the use of a BJM Pumps® wire connection kit. Included in this kit are specific instructions on how a qualified factory trained and certified repair technician can perform this work properly.
Fahrenheit™ Series high temperature pumps. The cable is designed for a high temperature environment. The proper replacement part can be found parts list found in this manual. BJM Pumps, can supply a control with the Seal Minder and Thermal sensor switch option. Separate stand alone Seal Minder alarm panels are also available.
BJM Pumps, LLC’s liability for any breach of this warranty shall be limited solely to replacement or repair, at the sole option of BJM Pumps, LLC, of any part or parts of the Product found to be defective during the warranty period, provided the Product is properly installed and is being used as originally intended. Any breach of this warranty must be reported to BJM Pumps, LLC or BJM Pumps, LLC’s authorized service...
START-UP REPORT FORM START-UP REPORT FORM This form is designed to record the initial installation, and to serve as a guide for troubleshooting at a later date (if needed). Industrial Flow Solutions Operating, LLC 104 John W Murphy Drive New Haven, CT 06513, USA Pump Owner’s Name Location of Installation Date of Installation:...
Page 61
START-UP REPORT FORM Are guide rails vertical? Is base elbow installed level? Liquid level controls: Model Is control installed away from turbulence? Float Operation Check Tip lowest float (stop float), all pumps should remain off. Tip second float (and stop float), one pump comes on. Tip third float (and stop float), both pumps on (alarm on simplex).
Page 62
START-UP REPORT FORM L1-L2 L2-L3 L3-L1 Amperage load connection, pump on FINAL CHECK Is pump secured properly? Was pump checked for leaks? Do check valves operate properly? Flow: Do pumps appear to operate at proper rate? Noise level: Acceptable Unacceptable Comments: Installed by: Company:...