The products described herein, including without limitation, product features, specifications, designs, availability and pric- ing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. The information in the product manual, including any apparatus, methods, techniques, and concepts...
DO NOT drill holes into the positioner. Drilling holes into the positioner can generate particles and ma- chining forces that may effect the operation of the positioner. Parker will drill holes if necessary; contact your local authorized distributor. DO NOT subject the unit to impact loads such as hammering, riveting, etc. Impacts loads generated by hammering or riveting may result in flat spots on bearing surfaces or misalignment of drive components.
MX45S Series Product Manual Encoder Specifications Description Specification Input Power 5 VDC +/-10% Analog < 100mA, Digital<200 mA depending on encoder Output Digital- Square wave differential line driver (EIA RS422A) 2 channels A and B in quadra- (Incremental) ture (90 ) phase shift.
Page 17
MX45S Series Product Manual Cabling and Wiring Diagrams Connector Pin Out and Extension Cable Wire Color Codes for the 1 and .1 micron and sin resolution encoders 006-2382-length 006-2409-length Limit Cable- Flying Lead Motor Extension Cable- Flying Lead L2, L4...
Page 18
Additionally, in X-Y Systems the overhung portion of the Y-axis may not met specifications due to the additional error caused by deflection and non-support of the base. Contact Parker for guidelines on specifications of overhang applications. ...
Page 19
MX45S Series Product Manual Limit Sensors Magnets for Optional Linear Encoder If the optional linear encoder option is ordered with the MX45S positioner, two limit magnets will be supplied that are not assembled to the positioner. These are supplied loose in the packaging so that they can be assembled at the desired locations or not assembled at all.
MX45S Series Product Manual Grounding / Shielding All cables are shielded. These shields are to be grounded to a good earth ground. Failure to ground shields properly may cause electrical noise problems. These noise problems may result in positioning er- rors and possible run away conditions.
MX45S Series Product Manual Chapter 4 - Performance Acceleration Limits Acceleration of linear servo driven tables is typically limited by four (4) factors: Linear Bearings The linear bearings used in the MX45S have a continuous acceleration limit of 2 g’s. This means that the bearings are designed to take repetitive accelerations of 2 g’s and maintain the rated...
MX45S Series Product Manual Chapter 6 - Maintenance and Lubrication Cross Roller Bearing and Screw Lubrication Materials Required : Replacement bearing and screw lubrication (See below for lubrication type and ordering information), clean cloth, small brush Lubrication Type Use: Mobil Vactra Oil No.2 on crossed roller bearings...
MX45S Series Product Manual Appendix A - Internal Protection Parker has conducted testing to determine the degree to which the positioner is protected by using a British standard called an Ingress Protection Rating (IP Rating). The MX45S has an IP 10 protec- tion rating.