Item
LED safety
Product safety
EMC
Other
No distruction
ESD
No malfunction
Dimensions
Weight
3.1
Ambient Light Immunity conditions
Ambient Light Immunity is measured using the following conditions:
Barcode Label:
Resolution
0.330 mm (13mil)
: α = 0°, β = +15°, γ = 0°
Angles
: R = ∞
Curvature
Note: α, β and γ respectively represent pitch, skew and tilt. Please see chapter 7.4 for details on how
these values are defined.
Specification
IEC 62471-1:2006 Exempt Group
EN60950-1:2005
IEC60950-1:2006
EN 55022:2010
EN 301 489-1 V1.9.2
EN 301 489-17 V2.1.1
EN 300 328 V1.8.1
FCC Part 15 Subpart C, Subpart B ClassB
Bluetooth logo certification
Air discharge (direct): ±15 kV
Contact discharge (direct / indirect): ±6 kV
Air discharge (direct): ±8 kV
44 × 25 × 140 (WDH mm)
Approx. 115 g
Figure 1: Ambient Light Immunity
Symbology
PCS
12-digit UPC
0.9
Note
Peak Wavelength
624 nm
For residential,
commercial and light-
industrial environments
Conditions:
IEC61000-4-2
compliant
Excluding battery
Size (mm)
No. of Digits
31.5 × 25.0
12
PX-36
V-1.0
9