Ambient Light Immunity Conditions; Figure 1: Ambient Light Immunity - Opticon PX-36 Specification Manual

2d data collector with bluetooth
Table of Contents

Advertisement

Item
LED safety
Product safety
EMC
Other
No distruction
ESD
No malfunction
Dimensions
Weight
3.1

Ambient Light Immunity conditions

Ambient Light Immunity is measured using the following conditions:
Barcode Label:
Resolution
0.330 mm (13mil)
: α = 0°, β = +15°, γ = 0°
Angles
: R = ∞
Curvature
Note: α, β and γ respectively represent pitch, skew and tilt. Please see chapter 7.4 for details on how
these values are defined.
Specification
IEC 62471-1:2006 Exempt Group
EN60950-1:2005
IEC60950-1:2006
EN 55022:2010
EN 301 489-1 V1.9.2
EN 301 489-17 V2.1.1
EN 300 328 V1.8.1
FCC Part 15 Subpart C, Subpart B ClassB
Bluetooth logo certification
Air discharge (direct): ±15 kV
Contact discharge (direct / indirect): ±6 kV
Air discharge (direct): ±8 kV
44 × 25 × 140 (WDH mm)
Approx. 115 g

Figure 1: Ambient Light Immunity

Symbology
PCS
12-digit UPC
0.9
Note
Peak Wavelength
624 nm
For residential,
commercial and light-
industrial environments
Conditions:
IEC61000-4-2
compliant
Excluding battery
Size (mm)
No. of Digits
31.5 × 25.0
12
PX-36
V-1.0
9

Advertisement

Table of Contents