3.2 Weight
The weight of the RS-3000 (excluding bracket) is: 50g
4 Environmental Specifications
Unless otherwise noted, these conditions apply to all environmental specifications where
applicable.
Environmental Specification Conditions
Condition
Barcode Sample
Distance
Angle
Curvature
Scanning Test
Power Supply Voltage
4.1 Temperature
Operating Temperature:
Storage Temperature:
Note: Temperature during charging should be between 0 and 45 °C. To protect the battery the RS-3000 will automatically
stop the charging process when the temperature is outside these values.
4.2 Humidity
Operating Humidity 5 to 90% RH (no condensation, no frost)
Storage Humidity
4.3 Ambient Light Immunity
Scanning performance is guaranteed when the illuminance on the surface of a barcode is
between zero and the following values:
Incandescent Light
Fluorescent Light
Sunlight
Note: Scanning performance is guaranteed if direct ambient light does not enter the light receiving section of the scan
engine.
4.4 LED light immunity
The scan performance of the RS-3000 is unaffected by indoor LED lighting applications.
4.5 Electrical Noise
There shall be no abnormalities when sinusoidal electrical noise (50 Hz to 100 kHz, smaller
than 0.1 Vp-p) is added to the power supply line via the USB port.
Description
0.33 mm UPC specified in Chapter 8
130 mm from the front edge of the scan engine
α = 0°, β =+15°, γ = 0°
R = ∞
Read at intervals of 300 ms
3.3 and 5.0 V
-20 to 60 °C
-40 to 70 °C
5 to 90% RH (no condensation, no frost)
10,000 lux
10,000 lux
100,000 lux
RS-3000 Specifications Manual