(1) Retaining nut of anchor plate
(3) Cabinet foot
(5) Bolt M12 % 70
(7) Big flat washer Φ12
(9) Expansion tube
Figure B-11 Fastening of anchor plate of the B68-22 cabinet
III. Fastening retaining nut of anchor plate
Fasten the retaining nut of the anchor plate according to part B in Figure B-11.
B.2.7 Insulation Test
Measure the resistance value between the fixing bolt M12 × 70 and the anchor plate
with a Multimeter. If the resistance value measured is larger than five meg-ohm, it
means the insulation is normal. Otherwise, it means that the cabinet is not insulated
Appendix B Installation of B68 Cabinet
(2) Anchor plate of the B68-22 cabinet
(4) Insulating washer of anchor plate
(6) Spring washer Φ12
(8) Insulating covering
(10) Expansion nut