Model Nomenclature - ClimateMaster Trilogy Q-Mode (QE) Series Manual

Table of Contents

Advertisement

1 2
3
Q E
V
SERIES
QE = Trilogy
Q-Mode
®
®
CONFIGURATION
V = Vertical Up
H = Horizontal - Straight
B = Horizontal - Back
D = Down Flow
UNIT SIZE
0930
1860
REVISION LEVEL
A = Mitsubishi Inverter
B = Carel Inverter (Model 1860 Only)
Safety
Warnings, cautions and notices appear throughout this
manual. Read these items carefully before attempting any
installation, service, or troubleshooting of the equipment.
DANGER: Indicates an immediate hazardous situation, which
if not avoided will result in death or serious injury. DANGER
labels on unit access panels must be observed.
WARNING: Indicates a potentially hazardous situation, which
if not avoided could result in death or serious injury.
The following warning complies with State of California law,
Proposition 65.
WARNING!
WARNING! This product exposes you to chemicals
including Carbon Black, which is known to the State of
California to cause cancer and Methanol, which is known
to the State of California to cause birth defects or other
reproductive harm. For more information go to
www.P65Warnings.ca.gov
Trilogy
®
Model Nomenclature: General Overview
8
4 5 6 7
0 9 3 0
A
G
VOLTAGE
G = 208-230/60/1
CONTROLS
E = EXM
c l i m a t e m a s t e r . c o m
Q-Mode
(QE) Series IOM - 60Hz HFC-410A
®
10
11
12
13
14
E
0 2 B L S
HEAT EXCHANGER OPTIONS
B = Micro Channel Air Coil w/ Brazed Plate
WATER CIRCUIT OPTIONS
2 = Internal Flow Controller High Head
CABINET
0 = Residential
CAUTION: Indicates a potentially hazardous situation or an
unsafe practice, which if not avoided could result in minor or
moderate injury or product or property damage.
NOTICE: Notification of installation, operation or maintenance
information, which is important, but which is not hazard-
related.
WARNING!
WARNING! All refrigerant discharged from this unit must
be recovered WITHOUT EXCEPTION. Technicians must
follow industry accepted guidelines and all local, state,
and federal statutes for the recovery and disposal of
refrigerants. If a compressor is removed from this unit,
refrigerant circuit oil will remain in the compressor. To
avoid leakage of compressor oil, refrigerant lines of the
compressor must be sealed after it is removed.
CAUTION!
CAUTION! To avoid equipment damage, DO NOT use
these units as a source of heating or cooling during the
construction process. The mechanical components and
filters can quickly become clogged with construction dirt
and debris, which may cause system damage and void
product warranty.
WARNING!
WARNING! To avoid the release of refrigerant into the
atmosphere, the refrigerant circuit of this unit must be
serviced only by technicians who meet local, state, and
federal proficiency requirements.
R e v i s e d : D e c e m b e r 2 2 , 2 0 2 1
15
STANDARD
S - Standard
RETURN AIR FLOW CONFIGURATION
L = Left Return w/ 2" Merv 11 pleated filter and frame
R = Right Return w/ 2" Merv 11 pleated filter and frame
3

Advertisement

Table of Contents
loading

Table of Contents