15. Sending Recorded Data

Recorded data can be sent to a connected computer or data collector.
Commands sent from a computer or the data collector instruct the
SDL30/50 to carry out measurement, and the measurement results are
output.
Important:
• The SDL30/50 accepts commands only when in status mode or
menu mode. Received commands are not executed in any other
state.

15.1 Connecting to a Computer or Data Collector

Use the dedicated communication cable to connect the
SDL30/50 to the data collector or a computer.
Communication cable
Computer
IBM PC/AT or
compatible
Other personal
computers
Cable
Notes
DOC26
Length: 2m
Pin Numbers and signal levels:
RS-232C compatible
DOC27
D-sub connector:
DOC26: 25 pins (female)
DOC27: 9 pins (female)
DOC1
No connector for attachment to
a computer.