2.4. Attaching the Focal Lens to the Scan Head
IMPORTANT: Wear clean, powder-free gloves when you handle optical components.
The procedure outlined in this section is provided as a general reference for how to remove or install
a focal lenses (F-Theta lenses). A lens adapter is required to attach the focal lens to the AGV-HP(O)
series scan head. This lens adapter is supplied with optics configurations that include a focal lens.
For AGV-HP(O) scan heads that are provided without a focal lens, the user is responsible for
supplying both the F-Theta lens and the necessary lens adapter. Contact the factory for assistance
with the design of an appropriate lens adapter if necessary.
Figure 2-15:
Example of F-Theta Lens (Complete Assembly)
DANGER: Make sure that the laser is set in the "off" position and secured against
accidental operation before you inspect or do maintenance to the focal lens.
www.aerotech.com
2.4. Attaching the Focal Lens to the Scan Head
43