Device Purpose Tracking device “BI-530P TREK” shall be applied to solve issues of navigation, remote control and monitoring of a vehicle or other remote object. The tracking device is designed to be installed on any mobile or remote stationary object in order to: ...
Outside GSM network coverage, the tracking unit operates in the “black box” mode, i.e., it records all information in the nonvolatile memory and sends it when the vehicle is entering a GSM coverage area. www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Weight of the device 75 g Housing protection class IP54 Housing material Plastic ABS UL94V0 Design of tracking device Appearance and dimensions of the tracking device “BI-530P TREK” are shown in Figure 1. www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Figure 1 – Appearance and design of the device. Supply package The tracking device “BI-530P TREK” is provided with the following set: 1. Tracking device “BI-530P TREK” – 1 piece. 2. Connection cable – 1 piece. 3. Technical data sheet – 1 piece.
Connecting cables in turn have outlets for power, analog, digital, discrete sensors and actuating mechanisms. Location of sockets and numbering of contacts are shown in Figure 3. Marking connector pins power supply, sensors peripherals is shown in Table 2. www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 8
Input/output Signal “TX” RS-232 Pink RS-232 RX Input/output Signal “RX” RS-232 Grey AN in 2 Input Analogue input No. 2 Green RS-485 B Input/output Signal “B” RS-485 Yellow/ 1-Wire Input/output 1-Wire data Green www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
UART service output socket is located on the board of the device next to the SIM-card slot. To access the socket, remove the side cover of www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Figure 4 – Connection of the cable of USB-UART converter to the device “BI-530P TREK”. Once connected, the device will transmit data about its state to the terminal. In addition, the user is able to use a terminal program to send commands to a device and receive response to them.
Adjustment of “BI-530P TREK” device Basic information The tracking device “BI-530P TREK” can be configured in following ways: 1. With a direct connection of the device to a computer. 2. Remotely, using SMS commands.
Page 12
Request of the version of the device software Command to be send – getver; Example of response: «BI-530P Ver: 0.0.7» Read the values of the device’s sensors. Command to be send – getio; Example of response: www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 13
Val – current value of parameter. Example of the command to request APN of the device (a parameter that contains the APN device has ID 0242) – getparam 0242; Example of response: «Param ID 0242 Val: gps.utel.ua». www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Param ID – ID of parameter to be set up; New Val – assigned value of parameter. Example of the command to set APN of the device (a parameter that contains the APN device has ID 0242) – setparam 0242 gps.utel.ua; www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 15
Command to be send – BOOT #,#,#; Example of command to update the software: «BOOT fw.bitrek.ua,80,*.bin;» , where: «HOST» - (fw.bitrek.ua,) is address of server locating the update files; «PORT» – (80,) – port of server locating the update files; «Firmware» (*.bin;) –...
ID 0261 – ID 0269 (Appendix 1). Total up to 9 phone numbers can be applied. When using this function, the device will respond to SMS from the stored in the memory authorized phone www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
7 – generation of the event to change the input value to a predetermined value; 8 – generation of the event to change the input value to a predetermined value + monitoring Averaging constant From 0 and higher www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 18
1 – Leaving the range. The event will be generated if the actual sensor value is outside the predetermined range. Example: The lower voltage limit is set to 0, the upper limit is set www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 19
4 – Monitoring + entering the range. When there is generated the event after entering the range, the actual value of the sensor starts to be transmitted to the server in the monitoring mode. www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
SMS, shall be defined as a trigger for outgoing SMS messages. In addition to the SMS message you can add customized text, where the text length shall not exceed 30 characters in the Latin alphabet. www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Roaming options The tracking device “BI-530P TREK” is able to operate in two modes: in the home network mode and in the operating mode with a predetermined list of authorized operators. Operation mode is set with ID 0917 parameter. In the home network mode (ID 0917 = 0), the device makes...
RS-485 “BI-530P TREK” tracking device enables work with fuel level sensors via RS-485. Up to four fuel level sensors can be connected in total. To work with fuel level sensors, enable in the device settings the...
0-9 or uppercase A-F. Each pair of symbols encodes one byte in ASCII representation. The first to be recorded is the low-order byte of electronic key, and etc. in ascending order, where in a pair of characters www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Only one reader CP-Z2L can be connected to the device. Configuring the device to work with CAN-LOG The device “BI-530P TREK” has the ability to work with the CAN- LOG device via the RS-232 interface. To enable the work, you must send the appropriate command: setparam 5007 1;...
5007 5; Receiver connector pinout is discribed at Figure.8. Figure 8. CUB receiver connector pinout Contact Signal type Description name Input/output Signal «TX» RS-232 Input/output Signal «RX» RS-232 Not connected Power Common wire (ground) www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
0908 1 byte configuration server (0 – disabled, 1 – enabled) IP or DNS of WEB configurator. settingsHost 0220 string configuration server bitrek.com.ua PORT of WEB settingsPort 0221 2 byte 55755 configuration server Period of connection to settingsTimeOut 0222 2 byte...
Page 27
Period of readout by Dist Period 0012 2 byte distance Period of readout by Angle Period 0013 2 byte degree azimuth Period of data transfer to Send Period 0270 2 byte second the server www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 28
1 byte accelerometer (0 – disabled; 1 – enabled) Wait_sleep_ Timeout to go to sleep 4007 2 byte timeout mode by accelerometer Timeout of sleep mode by Sleep timeout 4008 2 byte accelerometer www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 29
0252 string Access login by SMS SMS Password 0253 string Access password by SMS Access password to the Device_PIN 0910 string 11111 device Installation of PIN-code of SIM_PIN 0818 1 byte SIM-card operator www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 31
UsipTable 0020...0059 string operators List of APN of authorized UsAPNTable 0060...0099 string operators List of GPRS logins of UsLoginTable 0100...0139 string authorized operators List of GPRS passwords of UsPassTable 0140...0179 string authorized operators www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 32
Filter of discrete inputs (Duration less than the MinDuration 0349 1 byte 10 msec predetermined levels will be filtered) The permissible error in Max_HDOP 0998 1 byte 0.01 c.u. the horizontal plane www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 33
Polling period for 4 fuel 0197 1 byte fuel level sensors The period of polling the Ekey_period 0208 2 byte 1 sec identifier keys F coefficient for Kalman Factor F 0950 4 byte c.u. 1000000 filter www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 34
5 – CUB TPMS) Median filtering depth for dh1MedSize 4017 1 byte c.u. dHigh1F (from 1 to 256) Autosetting of CAN LOG I/O elements AutoSetIO_Ena 0408 1 byte c.u. 0 – disabled 1 - enabled www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Discrete input with active “0” No. 2 Dhigh1 0540/0541/0542/0543/0544/0545 Discrete input with active “1” AIN 1 0300/0301/0302/0303/0304/0305 Analog input No. 1 AIN 2 0310/0311/0312/0313/0314/0315 Analog input No. 2 Jamming 0940/0941/0942/0943/0944/0945 Status of GSM signal jamming www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 37
ID of approached RFID-card iMCC 4010/4011/4012/4013/4014/4015 Positioning by base stations* iMNC 4020/4021/4022/4023/4024/4025 Positioning by base stations* iLAC 4030/4031/4032/4033/4034/4035 Positioning by base stations* iCellID cell_id 4040/4041/4042/4043/4044/4045 Positioning by base stations* Rx_level rx_level 4050/4051/4052/4053/4054/4055 Positioning by base stations* www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 38
When using the Wialon IPS protocol, the values of the parameters id_Send 44, 45, 47 are transferred in “g” When using the Teltonika protocol, the values of the parameters id_Send 44, 45, 47 are transferred in “g * 100” www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Fuel level (in liters) 5130/5131/5132/5133/5134/5135 liter 0,1 L Engine speed 5140/5141/5142/5143/5144/5145 0,25 rpm Engine temperature 5150/5151/5152/5153/5154/5155 °С -60 °С offset Vehicle speed 5160/5161/5162/5163/5164/5165 km/h 1 km/h Load on axle 1 1600/1601/1602/1603/1604/1605 0,5 kg www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 40
Vehicle condition 5250/5251/5252/5253/5254/5255 Harvest time 5260/5261/5262/5263/5264/5265 Square of the treated 5270/5271/5272/5273/5274/5275 area Performance 5280/5281/5282/5283/5284/5285 ha/hrs Quantity of harvested 5290/5291/5292/5293/5294/5295 crop Moisture of grain 5300/5301/5302/5303/5304/5305 Threshing drum speed 5310/5311/5312/5313/5314/5315 Output concave 5320/5321/5322/5323/5324/5325 clearance www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 41
3 - info is unavailable Reserved (technical 5460/5461/5462/5463/5464/5465 information) Reserved (technical 5470/5471/5472/5473/5474/5475 information) Security state flags 5640/5641/5642/5643/5644/5645 D3 D2 D1 D0 Bit mask (0х1020) Security state flags 5650/5651/5652/5653/5654/5655 D7 D6 D5 D4 Bit mask (0х1020) www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 42
Security state flags D11 D10 5660/5661/5662/5663/5664/5665 Bit mask (0X1020) D9 D8 *Note: No. 37 - for a vehicle Toyota Hilux 2017 this parameter is describes a status of 4-wheel drive (4WD). www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
88 – monitoring RFID, key validation is active; 120 - monitoring iButton+RFID, key validation is active; Without control source, RFID and iButton monitoring mode only 96 – monitoring RFID+iButton, without key validation, without Out1 control www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
No.5 Air pressure of wheel 5200/5201/5202/5203/5204/5205 No.6 Air temperature of wheel 5210/5211/5212/5213/5214/5215 °С No.6 Air pressure of wheel 5230/5231/5232/5233/5234/5235 No.7 Air temperature of wheel 5240/5241/5242/5243/5244/5245 °С No.7 Air pressure of wheel 5250/5251/5252/5253/5254/5255 No.8 www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 45
Air temperature of wheel 5520/5401/5402/5403/5404/5405 °С No.13 Air pressure of wheel 5530/5531/5532/5533/5534/5535 No.14 Air temperature of wheel 5540/5541/5542/5543/5544/5545 °С No.14 Air pressure of wheel 5550/5551/5552/5553/5554/5555 No.15 Air temperature of wheel 5560/5561/5562/5563/5564/5565 °С No.15 www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 46
No.20 Air pressure of wheel 5080/5081/5082/5083/5084/5085 No.21 Air temperature of wheel 5090/5091/5092/5093/5094/5095 °С No.21 Air pressure of wheel 5100/5101/5102/5103/5104/5105 No.22 Air temperature of wheel 5110/5111/5112/5113/5114/5115 °С No.22 Air pressure of wheel 5220/5221/5222/5223/5224/5225 No.23 www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 47
Measurement ID at Name of parameter ID at configuration unit transmition Air temperature of wheel 5260/5261/5262/5263/5264/5265 °С No.23 Sensors bitmask 5270/5271/5272/5273/5274/5275 www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 48
Added detailed description of the parameter ID_Send 240 21.02.2019 2019.02.1 Added detailed description of ID_Send parameters 44, 45, 47 28.03.2019 2019.03.1 Added detailed description of ID_Conf parameters 0959, 0980 Changed ID_Send numbers of LBS I/O-elements 11.05.2019 2019.05.1 (189/190/191/192/193) www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Page 49
27.11.2019 2019.11.2 Added new I/O elements, ID_Send 219, 220, 221 Changed ID_Send number for parameter “Socket Status” from 177 16.01.2020 2020.01.1 to 139 04.06.2020 Ver.2020.06.1 Fixed units of measurement for parameter ID_Conf 0197 www.bitrek.com.ua sales@bitrek.com.ua +380 44 507 02 07...
Need help?
Do you have a question about the BI-530P TREK and is the answer not in the manual?
Questions and answers