PD6770 Field-Mount Loop-Powered Process Meter
Instruction Manual
• NEMA 4X, IP66 Field-Mount Loop-Powered Process Meter
• 4-20 mA Input
• 1 Volt Drop (4 Volt Drop with Backlight)
• 1.0" (25.4 mm) 3½ Digits LCD Display; -1000 to 1999
• Display Mountable at 0°, 90°, 180°, & 270°
• HART
Protocol Transparent
®
• Loop-Powered Backlight Option
• Operating Temperature Range: -40 to 75°C (-40 to 167°F)
• Zero & Span Potentiometer Adjustments for Easy Field Scaling
• Conformal Coated PCBs for Dust and Humidity Protection
• Wide Viewing Angle
• Flanges for Wall or Pipe Mounting
• Tag or Tamper Seal Loop
• Three 3/4" NPT Threaded Conduit Openings (Two Plugs Provided)
• 2" U-Bolt Kits Available
• Stainless Steel Tag Available
• 3-Year Warranty
PRECISION DIGITAL CORPORATION
233 South Street • Hopkinton MA 01748 USA
Tel (800) 343-1001 • Fax (508) 655-8990
www.predig.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vantageview PD6770 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Precision Digital Corporation Vantageview PD6770

  • Page 1 • Three 3/4" NPT Threaded Conduit Openings (Two Plugs Provided) • 2" U-Bolt Kits Available • Stainless Steel Tag Available • 3-Year Warranty PRECISION DIGITAL CORPORATION 233 South Street • Hopkinton MA 01748 USA Tel (800) 343-1001 • Fax (508) 655-8990 www.predig.com...
  • Page 2: Introduction

    Disclaimer The information contained in this document is subject to change without notice. Precision The Vantageview PD6770 is a rugged, loop-powered Digital Corporation makes no representations meter with 1" display digits. The plastic NEMA 4X and or warranties with respect to the contents hereof;...
  • Page 3: Accessories

    PD6770 Field-Mount Loop-Powered Process Meter Instruction Manual Accessories Useful Tools PD9501 Multi-Function Calibrator PDA1024-01 24 VDC Power Supply PDA1024-01 is a DIN rail mounted 1.5 A, 24 VDC power supply that can be used to power the 4-20 mA transmitter. PDA6846 2"...
  • Page 4: Table Of Contents

    PD6770 Field-Mount Loop-Powered Process Meter Instruction Manual Table of Contents Introduction ......................2 Ordering Information ..................2 Accessories ......................3 Useful Tools ......................3 Specifications ..................... 5 General ......................5 Input ........................ 5 Safety Information ..................6 Tag and Tamper Seal Loop ................6 PDA-SSTAG Stainless Steel Tag ..............
  • Page 5: Specifications

    PD6770 Field-Mount Loop-Powered Process Meter Instruction Manual Specifications Input Except where noted all specifications apply to operation at +25°C. Input 4-20 mA General Accuracy ±0.1% of full span ±1 count Display 3 ½ digit LCD Maximum Without With Loop-Powered 1" (25.4 mm); -1000 to 1999 Voltage Drop &...
  • Page 6: Safety Information

    PD6770 Field-Mount Loop-Powered Process Meter Instruction Manual Safety Information PDA-SSTAG Stainless Steel Tag • Read complete instructions prior to installation and operation of the meter. • Installation and service should be performed only by trained service personnel. Service requiring replacement of internal components must be performed at the factory.
  • Page 7: Installation

    PD6770 Field-Mount Loop-Powered Process Meter Instruction Manual Installation Dimensions All controls and wiring connections are located on the All units: inches (mm) display module that is accessed by removing the en- closure cover. The controls can be accessed without 3.35 (85.1) removing the display module.
  • Page 8: Connections

    PD6770 Field-Mount Loop-Powered Process Meter Instruction Manual Connections Wiring Diagrams To access the wiring connections, remove the enclo- Signal connections are made to a three-terminal con- sure cover and unscrew the two captive screws that nector mounted on the rear of the display module. fasten the display module.
  • Page 9: Setup

    PD6770 Field-Mount Loop-Powered Process Meter Instruction Manual Setup Setting Up the Meter Setting the Decimal Point Overview A decimal point may be set using a three-position Setting the 4-20 mA input for the desired display is jumper array located on the rear of the display done using a calibrated 4-20 mA signal source and module.
  • Page 10: Factory Default & User Settings

    PD6770 Field-Mount Loop-Powered Process Meter Instruction Manual Factory Default & User Settings Troubleshooting The rugged design and the user-friendly interface of The following table shows the factory setting for most the meter should make it unusual for the installer or of the programmable parameters on the meter.
  • Page 11 Fax: (508) 655-8990 Email: sales@predig.com Place Orders Email: orders@predig.com For the latest version of this manual please visit www.predig.com PRECISION DIGITAL CORPORATION 233 South Street • Hopkinton MA 01748 USA Tel (800) 343-1001 • Fax (508) 655-8990 www.predig.com LIM6770_C 06/21...

This manual is also suitable for:

Pd6770-0k0

Table of Contents