Honeywell DBC2000 Series Installation Instructions Manual page 19

Digital burner controller
Hide thumbs Also See for DBC2000 Series:
Table of Contents

Advertisement

Table a.
Volumes in dm3 for gas valves like Honeywell VE-series (Vp) with pipe length L (including V1 and V2). For combi blocks, like
VQ-M series and direct linked valves, use the values shown under L=0m.
Diameter
0
¼"
0.06
½"
0.06
¾"
0.12
1"
0.19
1¼"
0.69
1½"
0.71
2"
1.3
2½"
2.7
3"
2.9
DN65
3.2
DN80
4.4
DN100
6.5
Threaded connections: sizes in inches.
Flanged connections: sizes in DN
If L = 0m it means that valves are directly linked without pipe connections. Also applicable for combi-blocks (VQ-M series).
Length between valves [m]
0.5
1
0.1
0.14
0.15
0.24
0.28
0.43
0.44
0.68
1.1
1.5
1.4
2.0
2.3
3.3
4.4
6.0
5.4
7.9
4.9
7.5
6.9
9.4
10.5
14.4
19
1.5
2
0.18
0.22
0.33
0.42
0.59
0.74
0.93
1.2
1.9
2.3
2.7
3.3
4.2
5.2
7.7
9.3
10
13
8.2
9.8
12
14
18
22
ENI7003R8 KO65 2013
per extra
meter
0.08
0.18
0.31
0.49
0.8
1.3
2.0
3.3
5
3.3
5.0
7.9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents