7. Normal operation

7.5.8 STD Mode Settings

Selecting "STD Mode. Settings" displays the sub-menu shown below:
1. Working Mode Set
2.Power Rate Limit
3.Freq Derate Set
4.10mins Voltage Set
5.Power Priority
6.Initial Settings
7.Voltage PCC Set
This function is applicable by maintenance personnel only, wrong operation
will prevent the inverter from reaching maximum power.
7.5.8.1 Enable DRM/Logic Interface Settings
Please follow below settings to enable the DRM/Logic Interface function.
The setting is "OFF" by default. If the setting is set to "ON", but the external DRM controlling
device or logic interface relay is not connected or logic interface relay is opened, the inverter
will display "LimbyDRM" and the inverter output power will be limited to zero.
1. Select "Initial Settings"
2. Select "DRM" and set it to "ON"

7.5.9 Restore Settings

There are 5 items in initial setting submenu.
Restore setting could set all item in 7.5.7 special setting to default.
Thescreenshowsasbelow:
Are you sure?
YES=<ENT> NO=<ESC>
Figure 7.22 Restore Settings
PresstheEnterkeytosavethesettingaftersettinggridoff.
PresstheESCkeytoreturnthepreviousmean.
.50.
7. Normal operation

7.5.10 HMI Update

This section is applicable to maintenance personnel only.
Selecting "Updater" displays the sub-menu shown below:
HMI Current Ver.: 02
YES=<ENT> NO=<ESC>
Updater is for updating LCD firmware. Press the ENTER key to start the process.
Press the ESC key to return to the previous menu.

7.5.11 Internal EPM Set

This section includes two functions related to the smart meter.
Please refer to section 4.3 for detailed connection diagrams.
Function 1: Internal Export Power Management Function
Inverters can work with a smart meter to dynamically limit the export power of
the system. Zero injection can be achieved.
Smart meter can be installed either on the grid side OR the load side.
Function 2: 24 Hour Consumption Monitoring Function
Only applicable if Canadian Solar monitoring system is used.
Inverters can work with a smart meter to monitor the load consumption data for
the whole day and the data will be displayed on the Canadian Solar monitoring system.
Smart meter can only be installed on the grid side.