6. Operation

6.5.5 Power Control

Active and reactive power can be set through power setting button.
There are 5 item for this sub menu:
1. Set output power
2. Set Reactive Power
4. Rea_P With Restore
5. Select PF Curve
This function is applicable by maintenance personnel only, wrong operation
will prevent the inverter from reaching maximum power.

6.5.6 Calibrate Energy

Maintenance or replacement could clear or cause a different value of total energy. Use this
function could allow user to revise the value of total energy to the same value as before. If
the monitoring website is used the data will be synchronous with this setting automatically.
(see Figure 6.20).
YES=<ENT> NO=<ESC>
Energy:0000000kWh
Figure 6.20 Calibrate energy
Press the DOWN key to move the cursor, Press the UP key to revise the value. Press the
ENTER key to execute the setting. Press the ESC key to return to the previous menu.

6.5.7 Special Settings

This function is applicable by maintenance personnel only, wrong
operation will prevent the inverter from working properly.

6.5.8 STD. Mode Settings

There are 5 setting under STD. Mode settings.
1. Working mode
2. Power Rate limit
5.Initial Settings
This function is applicable by maintenance personnel only, wrong
operation will prevent the inverter from working properly.
.32.
3. Out_P With Restore
3. Freq. Derate set
4. 10mins OV-G-V set.
6.5.8.1 Enable logic interface settings
When select G98 or G99 standard to use the logic interface function, please follow below
settings to enable the DRM. DRM default setting is "OFF" , if DRM set "ON", but the logic
interface un-connected to the switch or the switch is open, the inverter HMI will display "Limit
by DRM" and the inverter output power will be limited to zero.
1. Select Initial Settings
2. Select DRM and set it "ON"

6.5.9 Restore Settings

Restore setting could set all item in 6.5.7 special setting to default.
Thescreenshowsasbelow:
YES=<ENT> NO=<ESC>
Figure 6.21 Restore Settings
PresstheEnterkeytosavethesettingaftersettinggridoff.
PresstheESCkeytoreturnthepreviousmean.

6.5.10 HMI Update

This function is used for update the LCD program.
These two functions are applicable by maintenance personnel only, wrong
operation will prevent the inverter from working properly.

6.5.11 Export Power Set

To access to this area is for fully qualified and accredited technicians only.
Pleasefollow6.4toenterpasswordtoaccessthismenu.
The default password is "0010". Please press "down" to move the cursor, press "up" to
selectthenumber.
Select EPMSettings from the Main Menu to access the following options:
1. Model Select
2.Set Backflow Power
6. Operation
Are you sure?
3.Fail safe ON/OFF
.33.