Fayat Dynapac DR7X Operating Instruction page 75

Table of Contents

Advertisement

Fig. 62
Fig. 63
Fig. 64
1
Pipe clamp
2
Screw M6x18
3
Screw M6x14
4
Screw M6x18
5.
Disassemble the guide handle fastening screws.
6.
NOTICE!
Components may get damaged!
Do not tear off any hoses or cables.
Remove the guide handle and secure it to the housing with a
fastening screw.
Tighten the fastening screw hand-tight.
7.
Disassemble the recoil starter.
DR7X
Maintenance – Annually
75