Monthly; Checking The Tamper Foot - Fayat Dynapac DR7X Operating Instruction

Table of Contents

Advertisement

8.7 Monthly

8.7.1 Checking the tamper foot

Fig. 54
Fig. 55
NOTICE!
Components may get damaged!
Use only oil of the permitted specification
Ä Chapter 8.3 „List of fuels and lubri-
cants" on page 65.
Protective equipment:
1.
Park the machine in secured condition
„Parking the machine in secured condition" on page 53.
2.
Park the machine so that the tamper foot is in horizontal posi-
tion.
3.
Allow the machine to cool down.
4.
Clean the sight glass.
5.
Check the oil level.
6.
The oil must be visible between the middle and the upper
edge of the oil level inspection glass, if necessary top up oil
up to the bottom edge of the filling opening.
The upper edge of the inspection glass
equals the bottom edge of the oil filling bore.
7.
Check concertina wall for condition, damage and tight fit.
8.
Check the hose clamps for tight fit, tightening torque for
screws (1): 10 Nm (7.4 ft·lbf).