Download Print this page
Pentair JBMB-56S Owner's Manual

Pentair JBMB-56S Owner's Manual

60 cycle centrifugal pump
Hide thumbs Also See for JBMB-56S:

Advertisement

Quick Links

INSTALLATION AND OPERATING INSTRUCTIONS
HP
MEDIUM HEAD MODELS
1/3
JBMB-56S
1/2
JBMC-56S
JBMC3-56S
1/2
3/4
JBMD-57S
JBMD3-57S
3/4
1
JBME-58S
JBME3-58S
1
1-1/2 JBMF-40S
JBMF3-40S
2
JBMG-41S
JBMG3-41S
2-1/2 JBMMG-59S
JBMMG3-59S
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.STA-RITE.COM
PH: 888-782-7483
© 2013 Pentair, Ltd. All Rights Reserved.
REPAIR PARTS LIST
MODELS
JMB-56L
JMC-56L
JMC3-56
JMCV-56L
JMC3V-56
JMD-57L
JMD3-57
JMDV-57L
JMD3V-57
JME-58L
JME3-58
JMEV-58L
JME3V-58
JMF-40L
JMF3-40
JMG-41L
JMG3-41
60 Cycle "J" and "JB" Series
Centrifugal Pump
671 0294
HIGH HEAD MODELS
JBHB-61S
JBHC-61S
JBHC3-61S
JBHD-62S
JBHD3-62S
JBHE-63S
JBHE3-63S
JBHF-51S
JBHF3-51S
JBHG-52S
JBHG3-52S
JBHHG-53S
JBHHG3-53S
OWNER'S MANUAL
JHB-61HL
JHC-61HL
JHC3-61H
JHD-62HL
JHD3-62H
JHE-63HL
JHE3-63H
JHF-51HL
JHF3-51H
JHG-52HL
JHG3-52H
JHHG-53HL
JHHG3-53H
S683 (Rev. 02/04/13)

Advertisement

loading
Need help?

Need help?

Do you have a question about the JBMB-56S and is the answer not in the manual?

Questions and answers

Summary of Contents for Pentair JBMB-56S

  • Page 1 JBHF-51S JBHF3-51S JHF-51HL JHF3-51H JBMG-41S JBMG3-41S JMG-41L JMG3-41 JBHG-52S JBHG3-52S JHG-52HL JHG3-52H 2-1/2 JBMMG-59S JBMMG3-59S – – JBHHG-53S JBHHG3-53S JHHG-53HL JHHG3-53H 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.STA-RITE.COM PH: 888-782-7483 S683 (Rev. 02/04/13) © 2013 Pentair, Ltd. All Rights Reserved.
  • Page 2 Short length of straight pipe after reducer Tee and Priming Plug Important: Priming All connections must Plug be air tight Discharge Street Elbow to service Support suction pipe Eccentric Union as required Reducer Gate Valve Solid, level base Vent Support discharge Straight run, short as Plug pipe as required...
  • Page 3 DISCHARGE PIPING California Proposition 65 Warning This product and related accessories contain Increase pipe size from pump tapping as show in Table I. chemicals known to the State of California to cause cancer, Figure 1 (Page 2) depicts a recommended run of pipe and birth defects or other reproductive harm.
  • Page 4 ELECTRICAL Connection diagram for dual voltage, single-phase Connect power supply wires to L1 and L2. For 3-phase motors. Your dual-voltage motor’s terminal board (under motors, or if motor does not match these pictures, follow the motor end cover) will match one of the diagrams the connection diagram on the motor nameplate.
  • Page 5: Pump Service

    SERVICE PUMP SERVICE INSTALLATION OF FLOATING SEAT (Figure 4C) 1. Clean polished surface of floating seat with clean cloth. This centrifugal pump requires little or no service other 2. Turn seal plate over so seal cavity is up, clean cavity than reasonable care and periodic cleaning.
  • Page 6 801 0394 SPC...
  • Page 8 2409 0496 SPC This drawing is for use with REPAIR PARTS LIST – “J” SERIES - MEDIUM HEAD Models using a capscrew configuration. MOTOR AND HORSEPOWER JMC-56L JMD-57L JME-58L JMC3-56 JMD3-57 JME3-58 JMCV-56L JMDV-57L JMEV-58L Part JMB-56L JMC3V-56 JMD3V-57 JME3V-58 Description Used 1/3 HP...
  • Page 9 2410 0496 SPC This drawing is for use with REPAIR PARTS LIST – “J” SERIES - MEDIUM HEAD Models using a stud configuration. MOTOR AND HORSEPOWER JMF-40L JMG-41L Part JMF3-40 JMG3-41 Description Used 1-1/2 HP 2 HP Motor, 115/230V, 1 Phase A100FLL –...
  • Page 10 2407 0496 SPC...
  • Page 12 This drawing is for use with Models having a capscrew configuration. 2409T 0496 SPC REPAIR PARTS LIST – “J” SERIES - HIGH HEAD MOTOR AND HORSEPOWER JBMB-56S JBMC-56S JBMD-57S JBME-58S Part – JBMC3-56S JBMD3-57S JBME3-58S Description Used 1/3 HP 1/2 HP...
  • Page 13 2410 0496 SPC REPAIR PARTS LIST – “J” SERIES - HIGH HEAD This drawing is for use with Models using a stud configuration. MOTOR AND HORSEPOWER JBMF-40S JBMG-41S JBMMG-59S Part JBMF3-40S JBMG3-41S JBMMG3-59S Description Used 1-1/2 HP 2 HP 2-1/2 HP Motor, 115/230V, 1 Phase A100FLL –...
  • Page 14 TROUBLE - CAUSES AND REMEDY TROUBLE AND CAUSE REMEDY FAILURE TO PUMP 1. Pump not properly primed. 1. Make sure pump casing and suction line are full of water. See priming instructions. REDUCED CAPACITY AND/OR HEAD 1. Air pockets or leaks in suction line. 1.
  • Page 15 Limited Warranty STA-RITE warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below. Product Warranty Period whichever occurs first: Water Systems Products —...