Page 2
Short length of straight pipe after reducer Tee and Priming Plug Important: Priming All connections must Plug be air tight Discharge Street Elbow to service Support suction pipe Eccentric Union as required Reducer Gate Valve Solid, level base Vent Support discharge Straight run, short as Plug pipe as required...
Page 3
DISCHARGE PIPING California Proposition 65 Warning This product and related accessories contain Increase pipe size from pump tapping as show in Table I. chemicals known to the State of California to cause cancer, Figure 1 (Page 2) depicts a recommended run of pipe and birth defects or other reproductive harm.
Page 4
ELECTRICAL Connection diagram for dual voltage, single-phase Connect power supply wires to L1 and L2. For 3-phase motors. Your dual-voltage motor’s terminal board (under motors, or if motor does not match these pictures, follow the motor end cover) will match one of the diagrams the connection diagram on the motor nameplate.
SERVICE PUMP SERVICE INSTALLATION OF FLOATING SEAT (Figure 4C) 1. Clean polished surface of floating seat with clean cloth. This centrifugal pump requires little or no service other 2. Turn seal plate over so seal cavity is up, clean cavity than reasonable care and periodic cleaning.
Page 8
2409 0496 SPC This drawing is for use with REPAIR PARTS LIST – “J” SERIES - MEDIUM HEAD Models using a capscrew configuration. MOTOR AND HORSEPOWER JMC-56L JMD-57L JME-58L JMC3-56 JMD3-57 JME3-58 JMCV-56L JMDV-57L JMEV-58L Part JMB-56L JMC3V-56 JMD3V-57 JME3V-58 Description Used 1/3 HP...
Page 9
2410 0496 SPC This drawing is for use with REPAIR PARTS LIST – “J” SERIES - MEDIUM HEAD Models using a stud configuration. MOTOR AND HORSEPOWER JMF-40L JMG-41L Part JMF3-40 JMG3-41 Description Used 1-1/2 HP 2 HP Motor, 115/230V, 1 Phase A100FLL –...
Page 12
This drawing is for use with Models having a capscrew configuration. 2409T 0496 SPC REPAIR PARTS LIST – “J” SERIES - HIGH HEAD MOTOR AND HORSEPOWER JBMB-56S JBMC-56S JBMD-57S JBME-58S Part – JBMC3-56S JBMD3-57S JBME3-58S Description Used 1/3 HP 1/2 HP...
Page 13
2410 0496 SPC REPAIR PARTS LIST – “J” SERIES - HIGH HEAD This drawing is for use with Models using a stud configuration. MOTOR AND HORSEPOWER JBMF-40S JBMG-41S JBMMG-59S Part JBMF3-40S JBMG3-41S JBMMG3-59S Description Used 1-1/2 HP 2 HP 2-1/2 HP Motor, 115/230V, 1 Phase A100FLL –...
Page 14
TROUBLE - CAUSES AND REMEDY TROUBLE AND CAUSE REMEDY FAILURE TO PUMP 1. Pump not properly primed. 1. Make sure pump casing and suction line are full of water. See priming instructions. REDUCED CAPACITY AND/OR HEAD 1. Air pockets or leaks in suction line. 1.
Page 15
Limited Warranty STA-RITE warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below. Product Warranty Period whichever occurs first: Water Systems Products —...