Carrier AddVolt User Manual page 5

Table of Contents

Advertisement

WARNING!
The removal of the label will result in warranty void of the product.
Operating Ambient
Temperature
Compliance and Safety
Battery Technology
Battery Lifetime
Charging
AC Installation Requirements
Frame and Enclosure
Systems: ADDM1507(R); ADDM1510(R); ADDM2014(R); ADDM2310(R); ADDM2517(R);
ADDM3014(R); ADDM3817(R); ADDL3021(R) may be used in load constantly at temperatures
below zero to avoid the battery internal temperature to drop below 0ºC for Charging and -11ºC
for discharging. These battery packs are only allowed to operate within these limits for its
internal temperature. It is of extreme importance to charge the system to 100% if the system is
not going to be operated for more than 60h.
For low ambient temperature performance, please cover the Battery side air inlets with the
special covers provided.
If, during operation, a problem occurs with the unit, before contacting the AddVolt customer
support, please have the following unit data available:
Serial number;
AddVolt unit model.
T
1 – A
ABLE
DDITIONAL SYSTEM SPECIFICATIONS
4000 cycles (80% DOD to 80% of rated capacity)
3x400V AC 50Hz, standard 5 pole 16/32A CEE socket
5
-20ºC to 40ºC
CE and ECE R10
Lithium Ion
On-board charger, 400V AC 50Hz
Stainless Steel
62-61974-01

Advertisement

Table of Contents
loading

Table of Contents