Sign In
Upload
Manuals
Brands
Carrier Manuals
Heat Pump
AquaSnap Touch Pilot Junior 30RQS
Carrier AquaSnap Touch Pilot Junior 30RQS Manuals
Manuals and User Guides for Carrier AquaSnap Touch Pilot Junior 30RQS. We have
1
Carrier AquaSnap Touch Pilot Junior 30RQS manual available for free PDF download: Installation, Operation And Maintenance Instructions
Carrier AquaSnap Touch Pilot Junior 30RQS Installation, Operation And Maintenance Instructions (58 pages)
Reversible Air-to-Water Heat Pumps
Brand:
Carrier
| Category:
Heat Pump
| Size: 4 MB
Table of Contents
Table of Contents
2
1 Introduction
4
Specific Aspects for 30RQSY Units with Variable Available Pressure
4
Check Equipment Received
4
Installation Safety Considerations
4
Equipment and Components under Pressure
6
Maintenance Safety Considerations
6
Repair Safety Considerations
7
2 Moving and Siting the Unit
9
Moving
9
Siting the Unit
9
Checks before System Start-Up
9
3 Installation Specifics for 30Rqsy Units
10
General
10
Duct Connection
10
Electrical Protection of the Fan Motors
11
Air Heat Exchanger Suction Filter Kit (Option 23B)
11
Applicable Rules for Units Incorporated into an Air Duct Network
11
Installation of the Accessory Condensate Collection Pan
11
4 Dimensions, Clearances
12
30RQS 039 and 045-078, Units with and Without Hydraulic Module
12
30RQS 080-160, Units with and Without Hydraulic Module
13
30RQSY 039-045, Units with and Without Hydraulic Module, Without Filter Frame
14
30RQSY 039-045, Option 23B, Units with and Without Hydraulic Module, with Filter Frame
15
30RQSY 050-078, Units with and Without Hydraulic Module, Without Filter Frame
16
30RQSY 050-078 Option 23B, Units with and Without Hydraulic Module, with Filter Frame
17
30RQSY 080-120 Units with and Without Hydraulic Module
18
30RQSY 140-160 Units with and Without Hydraulic Module
19
30RQS/RQSY 039-078 Units with Buffer Tank Module
20
30RQS/RQSY 080-160 Units with Buffer Tank Module
21
30QBS/RQSY 039-080 Units with Desuperheater
22
30RQS/RQSY 090-120 Units with Desuperheater
22
30RQS/RQSY 140-160 Units with Desuperheater
22
5 Physical Data, 30Rqs Units
23
6 Electrical Data, 30Rqs Units
24
7 Physical Data, 30Rqsy Units
25
8 Electrical Data, 30Rqsy Units
26
9 Electrical Data, 30Rqs and 30Rqsy Units
27
Electrical Data, Hydraulic Module
27
Compressor Usage and Electrical Data for Standard Units
28
10 Application Data
30
Operating Range, Standard Units - Cooling Mode
30
Operating Range, Standard Units - Heating Mode
30
Water Heat Exchanger Water Flow Rate
30
Minimum Water Flow Rate
31
Maximum Water Heat Exchanger Water Flow Rate
31
Water Loop Volume
31
11 Electrical Connection
32
Control Box
32
Power Supply
32
Voltage Phase Imbalance (%)
32
Recommended Wire Sections
32
Field Control Wiring
33
Power Supply
33
12 Water Connections
34
Operating Precautions and Recommendations
34
Hydraulic Connections
34
Frost Protection
34
Protection against Cavitation (Option 116)
35
13 Nominal System Water Flow Control
38
Units Without Hydraulic Module
38
Units with Hydraulic Module and Fixed-Speed Pump
38
Units with Hydraulic Module and Variable-Speed Pump - Pressure Differential Control
39
Units with Hydraulic Module and Variable-Speed Pump - Temperature Difference Control
39
Plate Heat Exchanger Pressure Drop (Including Internal Piping) - Units Without Hydraulic Module
40
Pump Pressure/Flow Rate Curve - Units with Hydronic Module (Fixed-Speed or Variable-Speed Pump, 50 Hz)
40
Available External Static Pressure - Units with Hydraulic Module (Fixed-Speed or Variable-Speed Pump, 50 Hz)
41
14 Start-Up
42
Preliminary Checks
42
Actual Start-Up
42
Operation of Two Units in Master/Slave Mode
42
Supplementary Electric Resistance Heaters
43
15 Major System Components
44
Compressors
44
Lubricant
44
Air Evaporator/Condenser
44
Fans
44
Electronic Expansion Valve (EXV)
44
Moisture Indicator
44
Filter Drier
44
Water Evaporator/Condenser
45
Refrigerant
45
High-Pressure Safety Switch
45
Storage Tank
45
Four-Way Valve
45
Control Box
45
16 Options
46
17 Specific Details for Units with a Fan with Available Static Pressure (30Rqsy)
48
18 Partial Heat Reclaim Using Desuper-Heaters (Option 49)
49
Physical Data, 30RQS/30RQSY Units with Partial Heat Reclaim Using Desuperheaters (Option 49)
49
Installation and Operation of the Heat Reclaim with Desuperheater Option
50
Installation
51
Control Configuration with the Desuperheater Option
51
Operating Limits
51
19 Brine Option (Option 5B & Option 6B)
52
Frost Protection
52
20 Standard Maintenance
53
Level 1 Maintenance
53
Level 2 Maintenance
53
Level 3 (or Higher) Maintenance
53
Tightening Torques for the Main Electrical Connections
54
Tightening Torques for the Main Bolts and Screws
54
Air Heat Exchanger
54
Water Heat Exchanger Maintenance
54
Refrigerant Volume
54
Characteristics of R-410A
55
21 Start-Up Checklist for 30Rqs/30Rqsy Heat Pumps (Use for Job File)
56
Advertisement
Advertisement
Related Products
Carrier AquaSnap Touch Pilot Junior Series
Carrier AquaSnap Touch Pilot Junior 30RQSY
Carrier AQUASNAP 30RB 017-040 A
Carrier AQUASNAP 30RQ 017-040 A
Carrier AQUASNAP 30RBY 017-033 A
Carrier AQUAZONE RHR
Carrier AQUAZONE RVR
Carrier AQUAZONE VQL
Carrier AQUASNAP 30RB060-390
Carrier AQUASMART
Carrier Categories
Air Conditioner
Heat Pump
Furnace
Thermostat
Chiller
More Carrier Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL