REsllNK S8 RESLINK Front view Front view Vue avant frontansicht Vi.sta frontale Vista Vue avant/ frontansicht Vista frontale Vista frontal / Vista frontal Vooruanzicht frontal Vista frontal Vooraanzicht cover (open) top catch couvercle (ouvert) patte d'attache superieure cover (open) Deckel (geof f n et)
• • • • • • • • • • • • RETU RNING THE RESLINK T O YOUR CLINICIAN RETU RNING THE SMARTMEDIA CARD TO YOUR CLINICIAN CLEANING AND MAINTENANCE • • • • • • • • •...
• The REsLINK is compatible for use with certain ResMed flow generators only. See • "Compatible flow generators" on page 18 for details. Do not use the REsLINK with other flow generators. Make sure that flow generator turned off before connecting or disconnecting •...
Page 8
Do not att e mpt to dismantle the There are no user serviceable parts REsLINK. • inside. Repairs and internal vicing should only be performed by an authorised agent There a serial (9-pin) port the back of some flow generators.
These accessories are available from ResMed. SETIING UP THE RESLINK See sections on the ill u strati o n sheet Note: Your clinician may have already set up the ResUnk you. INSERTING THE CARD...
Only the • Sensors are compatible with the Reslink. Connecting other oximeters may cause personal injury or damage to the flow generator or the Reslink. Check the oximeter cables and the oximeter sensor before use. If there is any •...
Note: more details, oximeter. please refer the user guide supplied with USING THE RESLINK on the flow generator. series of messages will be displayed on the flow generator LCD. When the following message is displayed, know that the RESLINK is cor rectly connected.
ResLink OXIMETER Oximeter not present ResLink COPYING, WAIT . . . Summary data being copied Card SmartMedia ResLink READY. Reslink ready to record Detailed Data ResLink Card SmartMedia has been re moved NO OXIMETER Oximeter discomected ResLink flow generator is...
Page 13
WAIT . . . minutes ResLink depending on amount transferred. Summary Da:ta being Indicates tha:t the Reslink finished copying Summary READY. Da:ta and is now ready to ResLink Detailed Data. This screen dears after a few seconds. USING THE RESLINK...
Page 14
These messages will be interspersed with other flow generator messages. Successful connection Reslink Sp02: 98% HR: 65 First oximetry message. OXIMETER There are 6 message s Each message is shown...
LINK to the left This unlocks RESLINK from the flow generator. (1-2, 1-3). Carefully pull the RESLINK away from the flow generator Store the RESLINK pouch. 58 RESLINK power off at the wall outlet To remove the S8 LINK from the flow generator;...
CLEANING AND MAINTENANCE CAUTION Avoid exposing the Reslink to moisture and extreme temperatures. CLEANING THE RESLINK REsLINK If necessary, wipe outside o with clean cloth. CLEANING THE OXIMETER . If necessary, wipe surfaces with a soft cloth dampened with isopropyl alcoho or a mild detergent.
RESLINK to flow generator. compatible for use with certain generator. ResMed flow generators only. "Compatible flow generators" on page The RESLINK may be See "Attaching the Reslink" attached incorrectly. pages. Flow generator and Power cord is plugged Check that the power cord is...
Page 18
RESLINK is in the lock position. Power the flow generator back For the S8 RESLINK make sure that the top and bottom latches are secured properly. Incompatible flow The RESLINK and S8 RESLINK are generator.
Page 19
Stop therapy. Power the flow off . delivering therapy. generator Check the power UPGRADE FAILED supply to the flow generator. Power the flow generator back "Using the Reslink" on page Difficulty inserting the Incompatible oximeter Ensure that a NONIN (Model 3012) oximeter into the RESLINK.
Page 20
SmartMedia Card. READ-ONLY CARD! Res Link The following message is The software on RESLINK This is OK. Wait for displayed on the LCD: itself is being upgraded, approximatel y three minutes. using data RESLINK should then start...
Dimensions (H 120 mm x 65 mm x 65 mm Weight: 14 g Power Supply: Maximum power consumption derived from the flow generator. 400mA RESLINK AND 58 RESLINK Housing Construction: Flame retardant engineering thermoplastic. IEC 60601-1 Class (double insulation). Type CF...
Page 22
COMPATIBLE FLOW GENERATORS Compatible with Reslink Compatible with SB Reslink AutoSet Spirit™ S8 AutoSet Spirit™ VPAP™ series Elite"' S7™ Elite AutoSet CSTM2 S8 AutoSet Vanta g VPAP™ Adapt SV S8 AutoSet Spirit™ VPAP™ Malibu EliteT S8 AutoScore™ VPAP™ Auto S8 AutoSet™...
Page 23
. resmed.com for other ResMed locations worldwide. patent information, see www.resmed.com/ip. Elite, AutoSet Spirit, AutoSet CS2, ResLink, S7 SB, SB AutoScore, SB AutoSet, SB AutoSet Spirit, SB AutoSet Vantage, VPAP. VPAP Adapt VPAP Auto. Malibu and VPAP Ill a VPAP re trademarks of ResMed.