Transport And Installation; Normal Operation - Gardner Denver L Series Original User And Service Manual

Hide thumbs Also See for L Series:
Table of Contents

Advertisement

2.7

Transport and Installation

Transport
A suitable forklift with sufficiently long forks must be used to transport the compressor. Dependent on type,
the compressor weighs up to 4,700 kg / 10,362 lbs.
Insert the forks only at the lifting points provided.
The compressor, even in its packed state, may not be transported by crane.
During transport, no person may be present in the hazard area. In particular, do not reach in or allow the
feet to pass beneath the suspended compressor.
Installation / Installation site
The compressor must be installed with full contact on a foundation with sufficient structural strength.
The installation site (compressor room) must be sized so that the compressor is sufficiently accessible
and the required cooling is ensured.
No flammable or explosive materials may be stored near the compressor.
2.8

Normal Operation

The compressor may be used only if it is in a technically pristine state, and it must be used as intended,
with awareness of safety and hazards, by following the operating instructions.
Operate the compressor only if all protective and safety devices, sound dampeners, ventilation and
exhaust devices, and cooling water supply (for water-cooled compressors only) are present and
functional.
Check regularly that:
All hoses and pipelines are in good condition and securely attached.
There are no leaks (oil, coolant, or cooling water).
The electrical connection lines are in good condition.
Cooling water supply is provided (for water-cooled compressors only).
Behavioral rules for using compressed air.
Do not use any method that involves questionable safety.
Never play around with compressed air.
Never direct compressed air at the skin or at other person.
Never use compressed air to clean clothing.
When using compressed air to clean equipment, use great care and also wear safety glasses as
eye protection.
Safety measures
Operate the compressor only when the enclosure is closed.
Check the compressor at least once per shift for externally visible damage and defects. Report any
changes (including to the operating performance) to the responsible location or person immediately.
Stop and secure the compressor immediately, if needed. Have faults repaired immediately.
Do not switch off or remove the exhaust and vacuum devices when the compressor is running.
Remote control
If there is a remote control, the compressor must bear a clearly visible sign with the following inscription:
"Caution! The compressor is remotely controlled and could start without warning."
In addition, safety precautions must be taken to ensure that no one is working on the compressor when
it is remotely controlled.
13-25-640 v00
Page 14