MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS

MEASUREMENTS "FROM UNIT" ARE FROM THE SIDE SHIELDS OF THE STOVE TO A SIDE WALL OR TO A CORNER, AND
NOTE: Be aware that local Codes and Regulations may override some clearances listed in this manual.
Check with your local inspector.
Residential Installation "C" Vent (Single Wall)
Unit
CS1203
Residential Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from
the stove collar to the ceiling level.
CS1203
Mobile Home Close Clearance (To be installed with required pipe components)
"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.)
CS1203
Regency CS1203 Freestanding Wood Stove
FROM THE REAR HEAT SHIELD TO A BACK WALL
B
E
A
D
From Unit
A
B
13"
11"
From Unit
A
B
11"
7"
From Unit
A
B
11"
7"
F
C
From Corner
C
D
8"
26-3/8"
From Corner
C
D
7"
24-1/2"
From Corner
C
D
7"
24-1/2"
INSTALLATION
F
C
From Flue Center-line
E
F
18-1/2"
20-3/4"
From Flue Center-line
E
F
14.5"
19-3/4"
From Flue Center-line
E
F
14.5"
19-3/4"