Room Air; Important; Minimum Clearance To Combustible Materials - Regency F2400M Owners & Installation Manual

Freestanding woodstove
Table of Contents

Advertisement

installation

rooM air

iMportant

For installation using room air for combustion,
remove knockout from the pedestal, and/or from
the bottom if using a heat shield.
Mobile home installations require the use of
outside air.
MiniMuM clearance to
coMBustiBle Materials
Please read the section below carefully as clearances depend on whether the airmate or the
rear heat deflector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner,
and from the rear heat shield to a back wall.
clearances may only be reduced by means approved by the regulatory authority.
note: Be aware that local Codes and Regulations may override some clearances listed in this manual.
Check with your local inspector.
residential installation "c" Vent (single Wall)
unit
Medium f2400M
with airmate
with rear deflector
Medium s2400M step stove
residential close clearance (to be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling
level.
unit
Medium f2400M
with airmate
with rear deflector
Medium s2400M step stove
Mobile Home close clearance (to be installed with required pipe components)
"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.)
unit
Medium f2400M
with airmate
with rear deflector
Medium s2400M step stove
8
On pedestal units there are two locations where
outside air may be adapted to the unit. If us-
ing the bottom of the pedestal, do not remove
knockout from the rear of the pedestal. Only
remove rear knockout if outside air will be
brought in from the rear.
On leg units outside air can only be brought in
from the bottom of the heat shield.
from unit
a
B
16" (406 mm)
11" (279 mm) 6" (152 mm)
18" (457 mm)
12" (304 mm) 6.5" (165 mm) 30" (762 mm)
16" (406 mm)
11" (279 mm) 6" (152 mm)
from unit
a
B
15" (381 mm)
5.5" (139 mm)
15" (381 mm)
6.5" (165 mm)
15" (381 mm)
5.5" (139 mm)
from unit
a
B
15" (381 mm)
5.5" (139 mm)
15" (381 mm)
6.5" (165 mm)
15" (381 mm)
5.5" (139 mm)
note: once the knockout is removed there
are two tabs remaining. Bend both
tabs out for ease of installation when
attaching outside air.
from corner
from flue center-line
c
d
28" (710 mm)
17.5" (444 mm)
18.5" (469 mm)
28" (710 mm)
17.5" (444 mm)
from corner
from flue center-line
c
d
4" (101 mm) 27" (685 mm)
12" (304 mm)
6" (152 mm) 27" (685 mm)
13" (330 mm)
4" (101 mm) 27" (685 mm)
12" (304 mm)
from corner
c
d
4" (101 mm) 27" (685 mm) 12" (304 mm)
6" (152 mm) 27" (685 mm) 13" (330 mm)
4" (101 mm) 27" (685 mm)
Regency Freestanding Woodstove
e
f
17.5" (444 mm)
19.5" (495 mm)
17.5" (444 mm)
e
f
15.5" (393 mm)
17.5" (444 mm)
15.5" (393 mm)
from flue center-line
e
f
15.5" (393 mm)
17.5" (444 mm)
12" (304 mm)
15.5" (393 mm)

Advertisement