Mitsubishi Electric PAC-YG21CDA Manual

C air conditioning network system

Advertisement

Quick Links

Mitsubishi Electric Air Conditioning Network System
PLC Software for General Equipment
Table Setting Tool
Please read this manual before using the unit.
Please keep this manual for future use.
1. Safety Precautions .......................................................................................... 1
2. Introduction...................................................................................................... 2
2-1 About This Manual ................................................................................. 2
2-2 Expressions in This Manual.................................................................... 2
2-3 Required Materials and Hardware Requirement .................................... 2
2-4 Image of Using Tool................................................................................ 3
3. Installing/Uninstalling the Table Setting Tool ................................................... 4
3-1 Installing the Table Setting Tool .............................................................. 4
3-2 Uninstalling the Table Setting Tool.......................................................... 5
3-3 Starting and Closing the Program .......................................................... 5
4. Screen Configuration and Various Utilities ...................................................... 7
4-1 Screen configuration .............................................................................. 8
4-2 Various utilities........................................................................................ 9
5. Table Setting.................................................................................................... 11
5-1 Screen Configuration of Table Setting .................................................... 11
5-2 Setting the Set File ................................................................................. 11
5-3 Setting the Set Value File ....................................................................... 12
5-4 Setting the Table File .............................................................................. 13
5-5 Selecting the Drive of ATA Card ............................................................. 21
5-6 Writing in ATA Card................................................................................. 21
6. Option Setting.................................................................................................. 23
6-1 Screen Configuration of Option Setting.................................................. 23
6-2 Reading from ATA Card .......................................................................... 23
7. Troubleshooting............................................................................................... 25
PAC-YG21CDA(Ver.2)
Contents
WT04265X04
(Ver.1.30)

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PAC-YG21CDA

  • Page 1: Table Of Contents

    Mitsubishi Electric Air Conditioning Network System PLC Software for General Equipment PAC-YG21CDA(Ver.2) Table Setting Tool Contents 1. Safety Precautions ..................1 2. Introduction...................... 2 2-1 About This Manual ................. 2 2-2 Expressions in This Manual..............2 2-3 Required Materials and Hardware Requirement ........2 2-4 Image of Using Tool................
  • Page 2: Safety Precautions

    Electric Corporation. By using this software, the user agrees to the conditions of the License. • Mitsubishi Electric and associated suppliers are not responsible for any collateral, secondary, or special damages, even if notified by the distributor of the possibility of a certain type of damage.
  • Page 3: Introduction

    • This instruction book describes the Table Setting Tool to set the operating function of the "PLC software for general equipment control (Ver.2)." *This table setting tool is applicable to Ver. 2 of the "PLC software for general equipment control." Model : PAC-YG21CDA (Ver.2 series) Table 2-1 Available version of table setting tool [V]: Available...
  • Page 4: Image Of Using Tool

    PARA.CSV TABLE.BIN (ATA card with the setting content written) *For the installation method of PAC-YG21CDA, refer to the installation (setup) manual. Notice The set content may be saved by the HDD of your PC in addition to the ATA card. Backing...
  • Page 5: Installing/Uninstalling The Table Setting Tool

    3. Installing/Uninstalling the Table Setting Tool Given below is an explanation on how to install and uninstall Table Setting Tool, and start and close the program. Installing the Table Setting Tool (1) Insert “Setup Disk of PLC software for General Equipment”...
  • Page 6: Uninstalling The Table Setting Tool

    (5) When the setup program has installed the program in the selected destination folder, the dialog shown on the right will appear. Click [Finish] to complete the installation process. Uninstalling the Table Setting Tool (1) To uninstall Initial Setting Tool, click [Start], point to [Settings] and click [Control Panel] to open Control Panel.
  • Page 7 (3) To close the program, click [File] then [Exit] from the Table Setting Tool menu.
  • Page 8: Screen Configuration And Various Utilities

    4. Screen Configuration and Various Utilities Given below are an explanation of the layout of the Table Setting Tool main window and an explanation on how to use the various utilities available from the menu bar. Outline of Table Settings ●STEP 1 (Setting the number of G-50A units to be connected.
  • Page 9: Screen Configuration

    Screen Configuration The screen of the table setting tool is consisted of 3 parts, the menu bar, setting menu section and setting sub-menu section. Clicking the setting item of the setting sub-menu section displays the screen for various settings. To execute various settings, click the item desired to set at the setting sub-menu section, and enter the set data on the setting screen displayed.
  • Page 10: Various Utilities

    Various Utilities Given below is an explanation of each type of utility that can be selected from the menu bar. 4-2-1 Reading setting data (1) Click [File]-[Open] from the menu bar. (2) Selecting the file storing the set data on the screen to select the directory allows reading the table set data, and selecting the set item displays the data on the setting screen.
  • Page 11 4-2-3 New creation To create set data newly, select [File ] - [New ] and click. In case of under setting presently or the file is being opened, a message prompts you whether destruct the current data. Select the proper button after confirming.
  • Page 12: Screen Configuration Of Table Setting

    5. Table Setting Here a method is explained to set the input/output relations or the output system of PLC for general equipment control to the table in compliance with the site. 5-1 Screen Configuration of Table Setting Clicking [Table setting] of the set menu section displays the table setting screen of PLC software for general equipment control.
  • Page 13: Setting The Set Value File

    Selecting the connecting number of G-50A Select the connecting number of G-50A to be controlled. The set value ranges from 0 to 2 sets. (Select "1set/2sets” to perform the interlock control.) [OK] button For saving the set detail [Cancel] button For returning to initial screen without saving set detail Figure 5-2.
  • Page 14: Setting The Table File

    5-4 Setting the Table File Clicking [Setting the table file] of the setting sub-menu section displays the wizard screen to set the input/output relations. On this screen, set the input source and output source relations and relating items. Notice The setting of input/output relations is to set the relationship between the input and output representing an event operation to operate the output of certain equipment when the input condition of the equipment changes.
  • Page 15 Supplementary Explanations for Table Settings Ctrl+C and Ctrl+V (or Ctrl+Insert and Shift+Insert) key combinations on the Windows can be used to copy and paste certain settings. Copying is done by row. If the setting in a single cell is copied and pasted, all the settings in the entire row will be copied and pasted, except that the equipment number under Classification 2 will automatically change to the number that is 1 larger than the one in the copy source.
  • Page 16 5-4-2 Selecting the output source On the [Selection of output source] screen representing the wizard screen for table file setting, select the object to be used for the output source. On this screen, in order to use it for the input/output relations, output source candidate is set up.
  • Page 17 5-4-3 Setting the input/output relations On the [Setting relating to input/output ] screen representing the wizard screen for table file setting, set the setting number of input/output and the input/output relations. On this screen, in order to set up input/output relation, set up from the candidate of the selected input and output source.
  • Page 18 Screen image when the Fahrenheit unit is selected Notice When the setting temperature shown below is selected, use G-50A, PAC-YG21CDA, indoor units, or remote controllers that have 1ºF temperature setting function. 54 56 58 60 62 64 66 70 72 74 76 78 80 82 ºF...
  • Page 19 At selecting the [Refer] button of input source; Clicking the [Refer] button of input source displays the contents set on the selecting screen of input source. You may select the input source from the candidates. (1) Clicking the [Refer] button displays the screen to select input sources.
  • Page 20 [Supplemental explanation of output detail setting] The operation detail of air conditioners is as shown in the table below. Table.5-1 - Setting detail of air conditioner operation Items Detail Remarks ON/OFF [ON] [OFF] Mode [COOL] [DRY] [FAN] [HEAT] *Set only functioning mode [AUTO] [19(12)] ~[28] The temperature range can be set to 12-18ºC...
  • Page 21 Example) When the output content of the output source is not selected (Supplement) This displays that the output content of the output source No.1 of the input/output relation No.1 is not being set. (2) Error message at duplication When the output source is duplicated under the same input source condition, the error message below will appear.
  • Page 22: Selecting The Drive Of Ata Card

    5-5 Selecting the Drive of ATA Card Clicking [Reference] of [ATA card drive] in the setting sub-menu displays the screen to select the drive. On this screen, select the drive in which PC card of ATA card is inserted. Selecting the drive For setting of the drive in which PC card is inserted.
  • Page 23 (3) To remove PC card in safe, right-click [Unplug or eject hardware] in the task bar to display and then select it. On the Unplug or Eject Hardware screen, select the device desired to remove, and click [Stop]. Then the screen to confirm is displayed.
  • Page 24: Option Setting

    6. Option Setting This section introduces how to read the set detail being written in ATA card. 6-1 Screen Configuration of Option Setting Clicking [Option] in the setting menu displays the option setting screen. On this screen, the set detail written in ATA card can be read.
  • Page 25 (1) Select the drive of PC card to read the set detail from ATA card. (2) Clicking the [Reading] button displays the screen for confirmation. Confirm the message and then click the [YES] button to display the finishing screen to read the set detail from ATA card. *Clicking the [NO] button returns to the initial screen without reading from ATA card.
  • Page 26: Troubleshooting

    7. Troubleshooting This section introduces the possible causes of and countermeasures against troubles occurred on this PLC for general equipment control and table setting tool. Table 7-1 Trouble causes and countermeasures Symptom of trouble Possible causes Countermeasures Unable to prohibit local From the operation item of Set [PROHIBIT] to the output source from remote controller operation...
  • Page 27 The following combination is possible. *The temperature unit increment on the PLC of displayed must be the This Table : Ver.1.30 or later PAC-YG21CDA is necessary. same in one system. Setting Tool (when the Fahrenheit is Which combination makes it selected)
  • Page 28 HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN WT04265X04...

Table of Contents