1 Safety Precautions

• Before installing the Electric Box, please read the following safety precautions carefully to ensure proper installation.
• Observe the following precautions to ensure safety.
• The following symbols are used in this manual to indicate the type and severity of potential consequences that may result when
given instructions are not followed exactly as stated.
WARNING
Indicates a risk of death or serious injury.
CAUTION
Indicates a risk of injury or damage to the product.
• After the completion of installation, perform a test run to confirm proper operation.
• Retain this manual for future reference. When the unit is reinstalled or repaired, make this manual available to those who provide
these services. Make sure that the manual is passed on to any future air condition system users.
Only a dealer or qualified technician should replace
the unit.
Improper replacement by an unqualified person may result
in electric shock or fire.
The Electric Box should be installed on a surface that
is strong enough to support the weight of the unit.
If the Electric Box is installed on a surface that lacks the
strength to support it, it may fall and cause injury.
Do not attempt to modify or repair the Electric Box.
Modification or improper repair may result in electric shock
or fire. Consult your dealer when repairs are necessary.
Do not install the Electric Box where there is a risk of
leaking flammable gas.
If the leaked gas accumulates around the Electric Box, it
may ignite and cause an explosion.
Do not use the Electric Box in an environment that has
high concentrations of oil, steam, or sulfuric gas.
These substances may have adverse effects on the
performance of the Electric Box or damage its parts.
Seal the wire access holes with putty to prevent dew,
water, and insects from entering to avoid electric
shock.
WARNING
Install the Electric Box properly according to the
instructions detailed in this Installation Manual.
Improper installation by an unqualified person may result in
electric shock or fire.
Electric work must be performed by authorized
personnel according to the local regulations and the
instructions detailed in the Installation Manual.
Inadequate circuit capacity or improper installation may
result in electric shock or fire.
Ask your dealer or an authorized technician to move
the Electric Box.
Improper installation by an unqualified person may result in
electric shock or fire. Consult your dealer or a qualified
technician.
CAUTION
Do not install this Electric Box in a place that has the
potential for steam, such as a bathroom or kitchen.
Steam may cause an electric shock or a unit malfunction.
Do not install this Electric Box where an acid, alkaline
solution, or special chemical spray is used frequently
to avoid electric shock or malfunction.
Keep the cables from coming in direct contact with the
edges of the wire access holes.
If the cables are damaged, they may cause electric shock
or fire.
This Electric Box is for exclusive use with the AG-150A
and cannot be used with other devices.
- 1 -
Applicable
Centralized Controller
AG-150A
Model

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PAC-YG83UTB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mitsubishi Electric PAC-YG83UTB

  • Page 1: Installation Manual

    AG-150A Model Air-conditioner Network System Optional Parts Electric Box for AG-150A PAC-YG83UTB Installation Manual 1 Safety Precautions • Before installing the Electric Box, please read the following safety precautions carefully to ensure proper installation. • Observe the following precautions to ensure safety.
  • Page 2: Parts List

    * If the Electric Box is installed on a non-wood surface, select an appropriate type of screws (4 pcs.) to suit the structure type. Check that the wall is strong enough to support the weight of the Electric Box (PAC-YG83UTB:2.0 kg). 3 External Dimensions 51 (2- 51 (2-...
  • Page 3: Selecting An Installation Site

    4 Selecting an Installation Site 1. Required installation space Install the electric box so that there is enough wall space around the Centralized controller AG-150A as shown below. Electric Box size (PAC-YG83UTB) 17.5 ( Centralized controller (AG-150A) size 300 ( 11-...
  • Page 4: Installation

    5 Installation 1. Installing the Electric Box (PAC-YG83UTB) 1 Rear installation To mount the rear of the Electric Box to a structure inside a wall, fix the Building structure Electric Box with the four mounting screws as shown in the right figure.
  • Page 5 3. Cutting a hole in the wall Cut a hole for the Electric Box in the wall. Cut a hole along the edges of the Electric Box opening. The opening should be exactly 278 mm (11 in) [W] × 152 mm (6 in) [H] to allow for a proper installation of the AG-150A. Cut a hole along the edges of the opening.
  • Page 6 2 Screw the A type installation plate down by putting the M4 flathead screws (supplied with AG-150A) through the mounting holes on the Electric Box. Mounting holes NOTE If a precise hole is cut out in as shown in Step 3 above, the screw holes on the A type installation plate will automatically be aligned with the screw holes on the Electric Box.
  • Page 7 5. Remove AG-150A surface cover. Insert a flat-tip screwdriver in the holes indicated and move the handle up to remove the cover. 6. Wiring Connect the cables to the AG-150A. Refer to the AG-150A Installation Manual for details. CAUTION * Do not put the signal wire and power wire in the same conduit. * When routing the cable from the top of the controller, let the cable hang down below the connector before connecting it to the terminal block or connector as shown in the figure below to prevent water from running down the cable and cause electric shock or fire.
  • Page 8 7. Sealing the cable access hole with putty Install a bushing at the end of a conduit tube, and seal the space in between with putty. Conduit Wall Lock nut Line lead-in port Bushing Electric box Seal with putty M-NET transmission cable or DC power cable 8.
  • Page 12 HEAD OFFICE: TOKYO BLDG. , 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Authorized representative in EU: MITSUBISHI ELECTRIC EUROPE B.V. HARMAN HOUSE, 1 GEORGE STREET, UXBRIDGE, MIDDLESEX UB8 1QQ, U.K. WT05420X01 Printed in Japan Recycled Paper...

Table of Contents