Air Supply Requirements
1. Supply tool with 90 psig (6.3 bar) of clean, dry air. Higher
pressure drastically reduces tool life.
2. Connect tool to air line using pipe, hose and fitting sizes shown
in the diagram below.
3/8" (10mm)
3/8" (10mm)
Using the tool
Remember that it is always the tool that must do the work. There
is no need for the operator to apply extra pressure on the tool
when it is working.
Maintain the contact with the work surface by applying enough
pressure to stop the tool from bouncing. In this way, the rust will
be removed from the surface more quickly. Use the tool on rigid
surfaces and prevent it from moving away from the edge, as this
can damage the needles.
Warning
1. Do not keep a tool running at free speed as this will lead to
premature wear of the moving parts.
2. Always use the right type of needle.
Lubrication
1. The hammer is lubricated with oil type like SHELL Natural HF or
CASTROL Carelube HTG 22 oil.
2. Daily check the oil level in the lubricator and oil flow adjustment.

Maintenance

1. To obtain maximum efficiency from the pneumatic tool, preserve
its features and avoid repeated repairs, a routine inspection and
repair programme are recommended at least every 1,000 hours,
the intervals between the various inspections depending on the
amount of exertion on the power tool.
2. Disassemble the tool, clean the parts with an appropriate solvent
and check them carefully.
3. Lubricate and reassemble the unit.
Original Instructions
Copyright 2012, Chicago Pneumatic Tool Co. LLC
All rights reserved. Any unauthorized use or copying of the contents
or part there of is prohibited. This applies in particular to trademarks,
model denominations, part numbers and drawings. Use only
authorized parts. Any damage or malfunction caused by the use of
unauthorized parts is not covered by Warranty or Product Liability.
1/2" (12 mm)
3/8" (10mm)
3/8" (10mm)
3/8" (10mm)
B16MV - B18MV - B19MV
B16BV - B18BV - B19BV
Technical Data
Model
Weight
Bore
B16BV
2.79 kg
23,5 mm
B18BV
3,07 kg
23,5 mm
B19BV
4,06 kg
34,4 mm
B16MV
2,41 kg
23,5 mm
B18MV
2,66 kg
23,5 mm
B19MV
3,56 kg
34,4 mm
Noise & Vibration Declaration
Soundpressure: ISO 15744
Model
Soundpressure dB(A)
B16MV
86,3
B18MV
85,9
B19MV
88,4
B16BV
88,6
B18BV
88,4
B19BV
92,8
Vibrations: ISO 28927-9 (3 axis)
Model
Vibrations a
m/s²
hd
B16MV
2,7
B18MV
2,7
B19MV
4,2
B16BV
4,8
B18BV
5
B19BV
4,6
All values are current as of the date of this publication. For the latest information
please visit cp.com. These declared values were obtained by laboratory type test-
ing in accordance with the stated standards and are suitable for comparison with
the declared values of other tools tested in accordance with the same standards.
These declared values are not adequate for use in risk assessments and values
measured in individual work places may be higher. The actual exposure values
and risk of harm experienced by an individual user are unique and depend upon
the way the user works, the workpiece and the workstation design, as well upon
the exposure time and the physical condition of the user. We, Chicago Pneumatic,
cannot be held liable for the consequences of using the declared values, instead
of values reflecting the actual exposure, in an individual risk assessment in a work
place situation over which we have no control. This tool may cause hand-arm
vibration syndrome if its use is not adequately managed. An EU guide to manag-
ing hand-arm vibration can be found at www.pneurop.eu/uploads/documents/pdf/
PN3-02-NV_Declaration_info_sheet_0111.pdf
We recommend a programme of health surveillance to detect early symptoms
which may relate to noise or vibration exposure, so that management procedures
can be modified to help prevent future impairment.
Needle scaler /Scaler
Stroke
Bl o w
air consumption
frequency
2.4 l/s
11 mm
2400
(5.1 cfm)
2.0 l/s
11 mm
2400
(4.2 cfm)
2.1 l/s
20 mm
3000
(4.4 cfm)
2.4 l/s
11 mm
2400
(5.1cfm)
2.0 l/s
11 mm
2400
(4.2 cfm)
2.1 l/s
20 mm
3000
(4.4 cfm)
Uncertainty KpA=KWA
Soundpower dB(A)
dB(A)
97,3
3
96,9
3
99,4
3
99,6
3
99,4
3
103,8
3
k: Uncertainty m/s²
1,2
1,3
2,6
2,2
1,9
1,7