Technical Data; 12 7.2 Ambient Conditions; Power Supply; Output - Balluff BTL6-P111-M0950-A1-S115 User Manual

Magnetostrictive linear position sensor - profile style
Hide thumbs Also See for BTL6-P111-M0950-A1-S115:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21
_
BTL6-P11
-M _ _ _ _ -A1-S115
Magnetostrictive Linear Position Sensor – Profile Style
7

Technical data

7.1
Accuracy
The values are typical at 24 V DC, room temperature and a
nominal length of 500 mm together with magnet
BTL6-A-3800-2 or BTL6-A-3801-2.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Resolution, position
Non-linearity at
nominal length ≤ 500 mm
nominal length > 500 mm
Hysteresis
Repeat accuracy, typical
Temperature coefficient
1)
Detectable velocity
7.2
Ambient conditions
Ambient temperature
Storage temperature
Relative humidity
Shock rating
Continuous shock
per EN 60068-2-27
2)
Vibration
per EN 60068-2-6
2)
Degree of protection as per
IEC 60529 with connector
installed
12
english
≤ 10 µm
± 200 µm
±0.04 % FS
(typ. ±0.02 % FS)
≤ 10 µm
≤ 10 µm
≤ 30 ppm/K
≤ 10 m/s
0 °C...+70 °C
−40 °C...+100 °C
< 90%, non-condensing
50 g/6 ms
50 g/2 ms
12 g, 10 ...2000 Hz
IP67
7.3

Power supply

Stabilized voltage
3)
Ripple
Current draw
(at 24 V DC)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength (GND to
housing)
7.4

Output

Start/stop difference
Max. number of magnets
4)
7.5

Dimensions, weights

Housing diameter
Nominal length
Weight (depends on length)
Housing material
Nominal length = 500 mm, magnet in the middle of the measuring range
1)
2)
) Individual specifications as per Balluff factory standard, resonant
frequencies excluded
3)
For
: The BTL must be externally connected via a limited-energy
circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1 or a class 2 power supply as defined in UL 1310 or UL 1585.
Number dependent on nominal length (see section 4.1)
4)
20...28 V DC
≤ 0.5 V
pp
≤ 90 mA
≤ 3 A
Up to 36 V
Up to 36 V
500 V DC
4
30 mm
50...4012 mm
Approx. 1 kg/m
Aluminum

Advertisement