Installing The Freestanding Cooker; Lpg Conversion - Westinghouse WFE904SD User Manual

900mm cooking appliances
Hide thumbs Also See for WFE904SD:
Table of Contents

Advertisement

INSTALLING THE FREESTANDING COOKER

Models
WFE904SD, WFE915SD, WFE916DSD,
WFEP917DSD & WFE946SD
Gas hose restraints
point to regulator
Models: WFE904SD,
WFE915SD,
Gas connection point
WFE916DSD,
to regulator
WFEP917DSD
Models: WFE904SD, WFE915SD,
WFE916DSD, WFEP917DSD
168
95
Gas pressures
The following table shows the supply and operating
pressures for various gases.
NATURAL
UNIVERSAL
GAS TYPE
GAS
LPG
Supply pressure at inlet
1.13 (kPa)
to appliance regulator
Minimum
(if fitted)
Operating pressure at
1.00 (kPa)
2.6 (kPa)
appliance test point
*If the regulator is placed upstream of the cooker inlet, as is normal
for cookers operating on LPG, then the supply pressure and
operating pressure are the same.
For WFE904SD and WFE915SD
The following table shows the injector sizes for
each burner.
NATURAL
UNIVERSAL
INJECTOR ORIFICE
GAS
LPG
Low heat burner
1.00mm
0.55mm
Medium heat burner
1.35mm
0.70mm
High heat burner
1.60mm
0.90mm
Intense heat wok burner
1.75mm
1.00mm
18
INSTALLING THE FREESTANDING COOKER
For WFE916DSD and WFEP917DSD
The following table shows the injector sizes for
each burner.
INJECTOR ORIFICE
NATURAL
GAS
Low heat burner
1.00mm
Medium heat burner
1.35mm
High heat burner
1.60mm
Electrical cable
Intense heat
0.96mm
entry point
dual wok burner
(inner)
Models:
WFE904SD,
3 x 0.58mm
WFE915SD,
(outer)
WFE916DSD,
WFEP917DSD,
WFE946SD
Checking piping size
To work out a suitable pipe size for connection use the
information in this table.
GAS TYPE
NATURAL
GAS
WFE914 & WFE904
49.6 MJ/h
WFE916 & WFEP917
54.2MJ/h
For information and requirements about construction
and capacity of consumer piping refer to AS5601 series
of standards.
Gas connection
Read these points before connecting to the gas supply:
• The appliance is preset for natural gas use, if LPG is to
be used see Conversion to LPG section.
2.75*
• Gas installation must be made in accordance with AS/
(kPa)
NZS 5601.1, the local gas fitting regulations, municipal
codes and other statutory regulations.
• The gas connection point is a ½" BSP external thread
located at the rear of the appliance as shown.
• The regulator is to be fitted to the manifold inlet at
the rear of the appliance and the connection is sealed
using a tape or jointing compound suitable for gas
connections. The consumer piping is then connected
to the inlet of the regulator, either
1. directly, or
2. using a hose assembly and in accordance
with Clause 6.10.1.9 of AS/NZS 5601.1 (High
level connection) together with the supplied
elbow. The elbow is fitted to the inlet of the
regulator and oriented to allow the hose to hang
downward. The connection thread between the
regulator and elbow is sealed using a tape or
jointing compound suitable for gas connections.
This appliance is supplied set up for Natural Gas usage.
LPG CONVERSION GAS COOKTOP MODEL
A conversion kit is included with the product for
Universal LPG usage. The conversion kit contains 5 or
7 injectors (refer to LPG conversion table) and 1 LPG
sticker.
Please follow the procedure below if a conversion to suit
UNIVERSAL LPG
UNIVERSAL LPG is required:
1. Remove the hotplate trivets, burner caps and burner
0.55mm
crowns to access the hotplate injectors. Replace the
factory fitted injectors with the appropriate injectors,
0.70mm
as supplied. Refer to injector orifice table for injector
0.90mm
sizes. The injector size is stamped on the side of
the injector.
0.52mm
(inner)
2. Unscrew the top hat nut from the regulator. The top hat
nut and control pressure spring assembly will disengage
3 x 0.58mm
as an assembly.
(outer)
3. Unscrew the threaded pin from top hat.
4. Upturn threaded pin, so spring is free and screw pin
back into the top hat until firm.
5. Refit the top hat nut assembly to the regulator
ensuring that it is fully screwed down. The regulator
is now set for connection to LPG.
UNIVERSAL
LPG
6. Turn on the gas supply and at each new connection
check for leaks using soapy water. Each hotplate
40.9 MJ/h
valve should be turned on, one at a time, and the
45.5MJ/h
injector hole blanked off for several seconds.
7. The operation of the regulator can be confirmed by
connecting a manometer to the pressure test point
located on the side of the regulator body adjacent
to the outlet.
With the appliance operating check the outlet pressure:
• when all burners of the appliance are operating
• when the smallest burner of the appliance is
Under these conditions the outlet pressure should
not vary from the nominal outlet pressure of
2.60kPa by more than ±0.52kPa.
8. If the regulator appears to not be performing
satisfactorily then check the following points:
• If the outlet pressure is consistently too low then
• Check that the insert has been fitted correctly.
• Check that the turret screw is fully
• Check that the regulator has been fitted to the
Once these checks have been completed, if the regulator
still fails to perform in a satisfactory manner it should
be replaced.
9. One by one, turn the knobs to minimum and screw
in the bypass screw (accessible when the knob is
removed) until a small stable flame results.
Turn the knob to maximum and then back to
minimum to ensure that the correct minimum
flame is maintained.
at maximum,
operating at minimum.
the inlet pressure may be too low and adjustment
of an upstream regulator may be needed, or an
upstream regulator or valve with insufficient flow
capacity may be present in the gas supply line.
If this is suspected then it may be necessary to
repeat the checks whilst measuring both the
inlet and outlet pressure to determine if the inlet
pressure is in the range 2.75 – 7.00kPa.
screwed down.
gas supply line in the correct orientation, the
arrow on the base of the body indicates the
direction of gas flow.
10. Attach the LPG sticker to the cooker, near the gas
supply inlet. Cover the Natural Gas label that is
factory fitted.
A
B
Turn top hat
nut anti-
clockwise
and remove
Top hat nut assembly, fully
screwed down
C
D
Configuration for
Natural Gas
E
F
Configuration for LPG
G
H
Bypass screw
Flame size adjusted
to maximum
Reposition
Flame size adjusted
Control knob shaft
to minimum
NOTE: You MUST test the cooker after installation,
before you hand it over to the customer. You MUST have
a manometer and a connecting tube.

LPG CONVERSION

19