Magtek MICR Plus Technical Reference Manual page 46

Rs-232 with optional 3-track msr
Table of Contents

Advertisement

MICR PLUS, RS-232
Fmt 68xx:
[transit] <TAB> [acct #] <TAB> [check #] <TAB> [amount] <TAB>
• [transit]:
- all characters in the field
- remove dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent
- remove spaces and dashes
• [check #]:
- all characters in the field
- remove dashes and spaces
• [amount]:
- all characters in the field
- remove dashes, spaces and leading zeros
- insert decimal point ('.') before 2nd rightmost digit
Fmt 69xx:
Read OK
Read error: '0' '/'
• [transit]:
- all characters in the field
- remove dashes
• [acct #]:
- always xx characters, trailing spaces;
- remove spaces and dashes
• [check #]:
- always 6 characters, zero filled
- remove dashes and spaces
Fmt 70:
[transit] ',' [acct #] ',' [check #] ',' [amount]
• [transit]:
- all characters in the field
- keep dashes
• [acct #]:
- always N characters (N is on quick-init check), space filled
- remove spaces and dashes from the account
• [check #]:
- always 8 characters, zero filled
- remove dashes and spaces
• [amount]:
- all characters in the field
- remove dashes and spaces
- if amount is not present, remove last ','
Fmt 71:
[acct #] '?' [check #]
• [acct #]:
- work with a window of N characters in the acct field
- always N characters (N is on quick-init check), zero filled
- remove spaces and dashes
• [check #]:
- maximum of 4 characters
- remove spaces and dashes
38