SX127X RF Module

5.2 Reflow Graph

6. FAQ

6.1 The communication distance is too close

When there's straight
Temperature, humidity and same frequency interference will increase the rate of communication packet loss.
Ground absorption, reflected radio waves, and closing to ground will lead to poor test result.
Sea water has a strong ability to absorb radio waves, so test near the sea is not recommended .
If antennas surrounded by metal items or placed in metal shell, the signal will be weakened badly.
Power register is set wrongly or air data rate too high.(The higher the air data rate, the closer the distance.
In room temperature, the power voltage will be less than 2.5V. The lower the the power voltage, the smaller the power.
The antenna is unmatched to the module or the quality of antenna.

6.2 The module can be damaged easily

Please check the power supply, which should be 1.8v-3.8v. If the value exceeds that, the module will be damaged.
Please check the stability of power supply. The voltage cannot be in fluctuations frequently.
Please ensure all the installation operations are anti-static.
Please ensure the humidity in the procedure of installation and operation should not be too high because some electrical parts are
humidity sensitive device.
Please do not use it in a too high or too low temperature environment if there's no special requirement.
Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co.,Ltd
Communication barrier, the communication distance will be reduced accordingly.