Ber(Bit Error Rate) Is High; Welding Operation Guidance; Reflow Soldering Temperature - Ebyte E22 T22S Series User Manual

At command 22dbm lora wireless module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd.
Please check the stability of the power supply. The voltage cannot fluctuate greatly and frequently ;
Please ensure anti-static operation during installation and use, as high-frequency devices are sensitive to static electricity ;
Please ensure that the humidity during installation and use should not be too high, as some components are humidity-sensitive
devices ;
If there are no special needs, it is not recommended to use it at too high or too low temperature.

12.3 BER(Bit Error Rate) is high

If there is co-channel signal interference nearby, stay away from the interference source or modify the frequency or channel to
avoid interference;
Unsatisfactory power supply may also cause garbled code, so be sure to ensure the reliability of the power supply;
Poor quality or too long extension cords and feeders can also cause a high bit error rate.

13. Welding Operation Guidance

13.1 Reflow soldering temperature

Reflow soldering curve characteristics
Minimum temperature
( Tsmin )
Preheat
Maximum temperature
/keep warm
(Tsmax )
Time (Tsmin ~Tsmin )
Temperature rise slope (
Liquidus temperature (
Holding time above
Package peak temperature Tp
The time (Tp ) within 5°C of the specified
classification temperature (Tc ), see the
figure below
Cooling slope (Tp ~TL )
Time from room temperature to peak
temperature
※The peak temperature (Tp) tolerance definition of the temperature curve is the upper limit of the user
Copyright©2012–2024, Chengdu Ebyte Electronic Technology Co., Ltd.
Lead process assembly
T
~Tp )
3℃/second, maximum
L
T
)
L
T
L
Users should not exceed the
temperature indicated on the
product's "Moisture Sensitivity"
label.
6℃/second, maximum
6 minutes, maximum
100℃
150℃
60-120 seconds
183℃
60~ 90 seconds
20 seconds
E22-xxxT22S series product user manual
Lead-free process assembly
150℃
200℃
60-120 seconds
3℃/second, maximum
217℃
60~ 90 seconds
Users should not exceed the
temperature indicated on the
product's "Moisture Sensitivity"
label.
30 seconds
6℃/second, maximum
8 minutes, maximum
29