GE IC3645SR7A353E1 Installation And Operation Manual page 20

Separately excited (sx) transistorized motor controllers for neighborhood electric vehicle applications
Table of Contents

Advertisement

INSTALLATION AND OPERATION
SX TRANSISTOR CONTROL
TRACTION
STATUS CODE
Accelerator voltage is too high.
-21
MEMORY RECALL
NO
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Traction
Accelerator input is mis-adjusted or
Controller
defective.
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
Motor field current is too high when the
-23
key switch is turned on.
MEMORY RECALL
NO
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Traction
Defective control.
Controller
DESCRIPTION OF STATUS
CORRECTIVE ACTIONS
Input voltage at P7 should be less than
4.5 volts after initial key switch closure.
Open wire exists between
potentiometer negative and P8.
Open wire exists between P7 and
potentiometer wiper.
CORRECTIVE ACTIONS
Replace controller unit.
CAUSE OF STATUS INDICATION
This status code will be displayed when the
accelerator voltage at P7 is greater than 4.5
volts.
TROUBLE-SHOOTING DIAGRAM
+72V
+72V
L
P1
P17
P2
P12
P3
+72V
72V
NEG
CAUSE OF STATUS INDICATION
This status code will be displayed when the current
draw in the motor field is too high on start up.
TROUBLE-SHOOTING DIAGRAM
NO GRAPHIC FOR THIS
STATUS CODE
Page 20
+72V
+72V
+72V
+72V +72V
P6
P4
P5
P21
P9 P7
P8
P15 P14 P16
P22
P23
P20
RS232
ACC POT
TACHOMETER
Updated Sept 2019