TECHNICALAND HEATING SPECIFICATIONS
H2OCEANO is designed to heat water by the combustion of
wood in the hearth.
The water contained in the thermo replace is heated and sent
into the heating system (radiators, heated towel rails, under o-
or heating panels) and also heats the room in which it is located
via natural convection radiation.
The thermo replace MUST NEVER FUNCTION WITHOUT
WATER IN THE SYSTEM.
The water heats up, circulating in the cavity that runs around
the entire semi-circular wall and dome of the hearth.
The hollow space is constructed in thick steel sheet.
The hearth is closed in the front by a door that slides up and
down and side to side for cleaning the glass.
INNOVATIVE PATENTED ASH GRILLE
This allows for the distribution of primary combustion air not
only from the bottom up, but also horizontally to achieve high
oxygenation of the ame, better combustion and increased power.
"GASKET-SAVING" DOOR
During sliding, the door remains slightly a ar from thermo re-
place inlet in order to protect the gaskets. In the closed position
the door is perfectly anked against the thermo replace to en-
sure maximum sealing and therefore optimal performance. The
handle is removable or it can be xed to the door (see pg. 28)
AUTOMATIC SMOKE BY-PASS
When turning on with the frame open, to facilitate combustion
start-up, the smoke damper (S) remains in the opening position
so that smoke can directly and easily reach the chimney ue.
When combustion has been started up, the smoke damper
also closes automatically when the door is closed (S - g. b).
In this mode, before reaching the chimney ue, the smoke
deviates in such a way to lap and give off heat to the water in
an ef cient manner.
The by-pass is automatically controlled by the door's move-
ment.
H
I
S
G
B
F
E
A
A
H
C
L
D
E
(a)
s
(b)
s
De ectors Ceilings
A
Grill motor housing
B
Post-Combustion
C
D
Automatic external air inlet adjustment valve (optional)
E
Possibility of applying adjustable feet (optional)
F
Calibration for automatic adjustment of combustion air
G
Up down sliding door
H
Enveloping cavity for water containment
Safety coil for thermal relief (CS version)
I
L
Primary combustion air distribution ash grille
S
Smoke diversion damper