Configuration Procedure Of Module; Notes For Aux - Ebyte E62-433T20S User Manual

433mhz 100mw wireless module
Hide thumbs Also See for E62-433T20S:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co,;Ltd

5.2.3 Configuration procedure of module

Only happened when power-on resetting or exiting sleep mode

5.6.4 Notes for AUX

No.
For function 1 & function 2 mentioned above, the priority should be given to the one with low level output, which means
1
if it meets each of any low level output condition, AUX outputs low level, if none of the low level condition is met, AUX
outputs high level.
When AUX outputs low level, it means the module is busy & cannot conduct operating mode checking. Within 1ms since
2
AUX outputs high level, the mode switch will be completed.
After switching to new operating mode, it will not work in the new mode immediately until AUX rising edge lasts for
3
2ms . If AUX stays on the high level, the operating mode switch can be affected immediately.
When the user switches to other operating modes from mode 3 (sleep mode) or it 's still in reset process, the module will
4
reset user parameters, during which AUX outputs low level.
Chengdu Ebyte Electronic Technology Co,;Ltd