Configuration Procedure Of Module; Notes For Aux; Operating Mode - Ebyte E22-400T22S1C User Manual

Asr6505 433/470mhz 160mw smd wireless module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd.

5.6.3 Configuration procedure of module

Only happened when power-on resetting or exiting sleep mode

5.6.4 Notes for AUX

No.
For function 1 & function 2 mentioned above, the priority should be given to the one with low level output, which means
1
if it meets each of any low level output condition, AUX outputs low level, if none of the low level condition is met, AUX
outputs high level.
When AUX outputs low level, it means the module is busy & cannot conduct operating mode checking. Within 1ms since
2
AUX outputs high level, the mode switch will be completed.
After switching to new operating mode, it will not work in the new mode immediately until AUX rising edge lasts for 2ms .
3
If AUX stays on the high level, the operating mode switch can be effected immediately.
When the user switches to other operating modes from mode 3 (sleep mode) or it's still in reset process, the module will
4
reset user parameters, during which AUX outputs low level.

6 Operating mode

There are four operating modes, which are set by M1 and M0, the details are as follows:
Mode(0-3)
M1
0 Normal mode
0
1 WOR mode
0
2 Configuration
1
mode
3 Deep sleep mode
1
Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co.,Ltd.
M0
UART and wireless channel are open, transparent
0
transmission is on
1
Can be defined as WOR transmitter and WOR receiver
Users can access the register through the serial port to
0
control the working state of the module
1
Sleep mode
Description
Description
E22-400T22S1C User manual
Remark
Supports configuration over air via
special command
Supports wake up over air
12

Advertisement

Table of Contents
loading