Chengdu Ebyte Electronic Technology Co,;Ltd
completing present mode task, which enables the user to omit the procedure of AUX inquiry and switch mode swiftly.
For example, when switching from transmitting mode to receiving mode, the user M CU can go dormancy before
mode-switch, using external interrupt function to get AUX change so that the mode-switch can be realized.
This operation is very flexible and efficient. It is totally designed on the basis of the user M CU's convenience, at the
5
same time the work load and power consumption of the whole system has been reduced and the efficiency of whole
system is largely improved.

6.2 Transmission mode (Mode 0)

Type
Ordinary
transmitting
operation
Continuous
transmitting
operation

6.3.Configure mode (Mode 1)

Type
Transmitting
Receiving

7.Instruction format

In command mode(mode 2:M1=1, M0=0), it supports below instructions on list.
Only support 9600 and 8N1 format when setting
No.
Instruction format
1
C0 + working parameters
2
C1 C1 C1
3
C2 + working parameters
Chengdu Ebyte Electronic Technology Co,;Ltd
Copyright ©2012–2019,
When M0 = 0, module works in mode 0
User can transmit the data when the modules are synced (PINLOCK = 1(high level)).
Benefit of the TDD feature, user can perform transmitting while receiving. The maximum
size of the data which can be transmit at one time is 2048 Bytes. After the AUX has
turned to 0(low-level), User can perform another 2048 Bytes transmitting operation. The
TDD feature is available whatever the air data rate or the baud rate is.
The module can transmit data continuously with some particular combination of air data
rate and baud rate, which has been show below.
Air Data Rate = 16Kbps, Baud rate <= 2400bps;
Air Data Rate = 32Kbps, Baud rate <= 4800bps;
Air Data Rate = 64Kbps, Baud rate <= 9600bps;
Air Data Rate = 128Kbps, Baud rate <= 19200bps;
Notes: Although higher air data rate brings lower transmission delay and it allows user
transmits the data continuously at higher baud rate, the communication range will be
shorter.
When M0 = 1, module works in mode 1.
N/A. User can configure the module at baud rate = 9600bps, parity = 8N1.
N/A. User can configure the module at baud rate = 9600bps, parity = 8N1.
C0 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and must
be send in succession.
( Save the parameters when power-down )
Three C1 are sent in hexadecimal format. The module returns the saved parameters and
must be send in succession.
C2 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and must
be send in succession. ( Do not save the parameters when power-down )