Chengdu Ebyte Electronic Technology Co,;Ltd
1
ID
Frequency-hopping sequence ID
(default 01H)
2
FHSS
The quantity of frequency hopping channel
nums
(default 0AH)
3
SPED
Rate parameter, including UART baud rate
7, 6 UART parity bit
-----------------------------------------
5, 4, 3
-----------------------------------------
2, N/A
-----------------------------------------
Chengdu Ebyte Electronic Technology Co,;Ltd
Copyright ©2012–2019,
and air data rate
00:8N1(default)
01:8O1
10:8E1
11:8N1(equal to 00)
TTL UART baud rate(bps)
000:1200bps
001:2400bps
010:4800bps
011:9600bps(default)
100:19200bps
101:38400bps
110:57600bps
111:115200bps
1, 0
Air data rate(bps)
00:16Kbps
01:32Kbps
Frequency-hopping sequence is decided by frequency -
hopping ID, both sides must keep the same.
Both sides must keep the same. The more quantity of
frequency-hopping channel, the better anti-interference
while synchronization time is longer for both sides.
Otherwise the less quantity of frequency -hopping channel,
the worse anti-interference while synchronization time is
shorter.
UART mode can be different between communication
parties
-----------------------------------------------
UART baud rate can be different between communication
parties
The UART baud rate has nothing to do with wireless
transmission parameters & won't affect the wireless
transmit / receive features.
----------------------------------------------
0 is recommended.
----------------------------------------------
The lower the air data rate, the longer the transmitting
distance, better anti-interference performance and longer
transmitting time
The air data rate must keep the same for both