Configuration Procedure Of Module; Operating Mode - Ebyte E70-900T14S User Manual

Cc1310 868/915mhz smd wireless module
Hide thumbs Also See for E70-900T14S:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co,;Ltd
when AUX=0, the internal 1024 bytes data in the buffer have not been written to the RFIC completely. If the user
starts to transmit data at this circumstance, it may cause overtime when the module is waiting for the user data, or
transmitting wireless sub package.
When AUX = 1, it does not mean that all the UART data of the module have been transmitted already, perhaps the
last packet of data is still in transmission.

5.6.3 Configuration procedure of module

Only happened when power-on resetting or exiting sleep mode

6. Operating Mode

The table below shows the status of corresponding modes: 
Mode (0-7)
0 RSSI mode
Chengdu Ebyte Electronic Technology Co,;Ltd
Copyright ©2012–2021,
M2
M1
M0
UART opens. Wireless closes and
0
0
0
transmission is unavailable.
Mode introduction
E70-900T14S user manual
Remark
Module outputs RSSI value each 100ms
through UART