Yaesu FT DX 9000 Series Technical Supplement page 61

Hide thumbs Also See for FT DX 9000 Series:
Table of Contents

Advertisement

FM MAX Deviation Adjustment
Press the [MNU] key momentarily to enter the
Menu ("Set") mode.
Rotate the Main Dial knob to select Menu item
"MODE-FM 059 FM MIC SELECT."
Rotate the CLAR/VFO-B knob to set this Menu
item to "REAR."
Press and hold in the [MNU] key for 2 seconds
to exit from the Menu ("Set") mode.
Connect the Dummy Load, Wattmeter, and De-
viation Meter to the "ANT 1" Jack.
Set the MAIN Band (VFO-A) frequency to 28.700
MHz in the FM mode.
Connect the Audio Generator to pin 8 of the MIC
jack (pin 7: GND) on the rear panel, then set the
output level to 10 mV @1 kHz.
Press and hold in the [ANT1], [ANT3], and [RX
ANT] keys, while turning the radio on, to enter
the alignment mode.
Rotate the Main Dial knob to select the Align-
ment Parameter "C59."
Press the PTT switch, then rotate the CLAR/VFO-
B knob for 4.5 kHz (±0.2 kHz) on the Deviation
Meter.
Release the PTT switch.
Rotate the Main Dial knob to select the Align-
ment Parameter "C60."
Set the MAIN Band (VFO-A) operating mode to
the FM-N mode.
Press the PTT switch, then rotate the CLAR/VFO-
B knob for 2.25 kHz (±0.15 kHz) on the Deviation
Meter.
Release the PTT switch.
Press and hold in the [MNU] key for 2 seconds
to exit from the alignment mode.
SWR Meter Adjustment (D version)
Referring to table
at the right, tune
the MAIN Band
( V F O - A ) f r e -
quency to each fre-
quency listed.
Connect the 50-
O h m D u m m y
Load and Wattmeter to the "ANT 1" Jack, then
set the METER switch to the "SWR" position.
Switch the TFT display to the Temperature/SWR
Indication Screen.
Disconnect the 3-pin plug from J2516 on the TX
Unit, then apply a –2.8 V DC voltage to pin 2 of
J2516, and –0.7 V DC to pin 3 of J2516.
Set the MAIN Band (VFO-A) frequency to 1.85
MHz in the USB mode.
Press the PTT switch, then adjust VR2505 on the
TX Unit for an SWR reading of 3.0 on the SWR
meter on the TFT Display.
Release the PTT switch.
Press and hold in the [ANT1], [ANT3], and [RX
ANT] keys, while turning the radio on, to enter
the alignment mode.
Apply a –7.0 V DC voltage to pin 2 of J2516, and
–0.7 V DC to pin 3 of J2516.
Rotate the Main Dial knob to select the alignment
parameter "C61A."
Press the PTT switch, then rotate the CLAR/VFO-
B knob for an SWR reading of 1.5 on the SWR
meter.
Release the PTT switch.
Perform the same procedures for the Alignment
Menus "C61b" through "C63c," per the chart
below.
A
LIGNMENT
P
P
2
ARAMETER
IN
C61A
–7.0 V
C61b
–4.2 V
C61c
–2.8 V
C62A
–7.0 V
C62b
–4.2 V
C62c
–2.8 V
C63A
–7.0 V
C63b
–4.2 V
C63c
–2.8 V
Press and hold in the [MNU] key for 2 seconds
to exit from the alignment mode.
Re-connect the 3-pin plug to J2516.
Alignment
1.8 MHz Band
1.850 MHz, USB
3.5 MHz Band
3.570 MHz, USB
7 MHz Band
7.100 MHz, USB
10 MHz Band
10.100 MHz, USB
14 MHz Band
14.200 MHz, USB
18 MHz Band
18.100 MHz, USB
21 MHz Band
21.200 MHz, USB
24.5 MHz Band
24.900 MHz, USB
28 MHz Band
28.700 MHz, USB
50 MHz Band
52.000 MHz, USB
J2516
SWR
M
P
3
V
R
ETER
IN
OLTAGE
ATIO
–0.7 V
10:1
1.5
–0.7 V
6:1
2.0
–0.7 V
4:1
3.0
–0.7 V
10:1
1.5
–0.7 V
6:1
2.0
–0.7 V
4:1
3.0
–0.7 V
10:1
1.5
–0.7 V
6:1
2.0
–0.7 V
4:1
3.0
ALIGNMENT-31