Mounting Holes - Omron VX Series Manual

Miniature basic switch
Table of Contents

Advertisement

VX
Dimensions
Terminals
Note: 1. All units are in millimeters unless otherwise indicated.
2. The following is for the SPDT contact specifications.
Terminal type
COM bottom position
Terminal dimensions
Note: The length to the center of the 1.6-dia. holes.

Mounting Holes

Two, 3.1-dia. mounting holes
or M3 screw holes
22.2 ± 0.1
Dimensions and Operating Characteristics
Note: 1. All units are in millimeters unless otherwise indicated.
2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
3. The following illustrations and drawings are for solder terminals (Terminal A). Illustrations for Terminal C2 are omitted. For details,
refer to Terminals.
4. The j in the model number is for the terminal code.
A: Solder terminals
C2: Quick-connect terminals (#187)
5. The operating characteristics are for operation in the A direction ( ).
Pin Plunger Models
PT
VX-5-1j2
VX-5-1j3
VX-01-1j2
2.8
OP
VX-01-1j3
3.1
3.4±0.15 dia.
Short Hinge Lever Models
VX-51-1j3
VX-011-1j3
PT
2.8
OP
3.4±0.15 dia.
130
Solder terminals (A)
(5.5)
(6.5)
2.9
(10)
t=0.5
Three, solder terminals
6.35
3.2 (see note)
4.75±0.1
1.6 dia.
2.4 dia.
10.3 ± 0.1
+0.13
20.2±0.25
3.1
A
–0.03
2.8
10.3±0.1
+0.13
–0.03
1.6
2.8
22.2±0.1
27.8
(10)
37.8±0.8
t = 0.5 (stainless-steel lever)
A
3.1
22.1
8.1
10.3±0.1
+0.13
3.1
–0.03
1.6
2.8
22.2±0.1
(10)
27.8
37.8±0.8
Quick-connect terminals (#187) (C2)
4.2
dia. holes
2.8
15.9 18.8
10.3
Three, solder terminals
4.3
+0.13
dia. holes
–0.03
2.8
15.9 18.8
10.3
Three, solder terminals
(5.5)
(6.5)
2.9
(10)
t=0.5
Three, quick-connect terminals (#187)
6.35
3.2
4.75±0.1
1.6-dia. terminal hole
Model
VX-5-1j2
VX-01-1j2
OF max.
0.25 N {25 gf}
0.49 N {50 gf}
{
g }
RF min.
0.03 N {3 gf}
0.05 N {5 gf}
PT max.
1.2 mm
OT min.
1.0 mm
MD max.
0.3 mm
OP
14.7±0.4 mm
Model
VX-51-1j3
OF max.
0.49 N {50 gf}
{
g }
RF min.
0.04 N {4 gf} (reference value)
PT max.
1.6 mm
OT min.
0.8 mm
MD max.
0.5 mm
OP
15.2±0.5 mm
Note:
The values indicated in parentheses
are reference values for cases when
the installation direction is such that
the lever weight is not applied to the
plunger.
VX
VX-5-1j3
VX-01-1j3
{
g }
VX-011-1j3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vx-5-1a3Vx-5-1a2

Table of Contents