WARNINGS:
!
Installation, electrical connection and setting up of the pump must be carried out by
skilled personnel in compliance with the general and local safety regulations in force.
Failure to abide by these instructions invalidates every right to the guarantee, as well as
endangering persons and things.
This device can be used by children at age at least 8 years and by people with limited
physical and mental abilities, and by people with lack of experience and knowledge, if
instruction concerning safty use of the device will be provided, so that
the associated risks will be understood. Children should not play with
the device. Children should not be allowed to clean and maintain the
equipment.
RANGE OF USE:
This circulation pump is suitable for drinking water only.
t1 – liquid temp. (from 2 to 95°C)
t2 – ambient temp. (from 2 to 40°C)
Note: The ambient temperature must be lower than the liquid tempera-
ture t1 > t2. See pict. 1
INSTALLATION:
Pump must be installed in vertical position, according to the picture no. 2.
The arrow stamped on the pump body indicates the direction of flow.
See pict. 2.
pict. 2
Follow the steps shown at pict. 3. Install two shut-off valves on pump's inlet and outlet,
after pump installation open both inlet valve and airvent valve. After filling up the instal-
lation remember to remove the air from the piping. Do not let the power cord contact
with hot parts of the pump or installation.
pict. 3
ELECTRICAL CONNECTION:
Supply voltage and frequency must be the same as shown
on the data plate. The circulation pump must ALWAYS BE
CONNECTED TO EARTH. Electrical connections must be
done according to local regulations. Connect the power sup-
ply AFTER finishing all other installation works. See pict. 4,
Read the yellow warning label before starting the pump.
STARTING-UP THE PUMP
Make sure that pump is correctly installed into the pipe-
work, all hydraulic connections are tight, and the air is re-
moved from the pipework. The pump is lubricated by the
pict.1
pict. 4