Model
Operating range
Head pressure
Fluid temperature
Type of pumped fluid
Max. pressure
Min. inlet pressure
Protection class
Insulation class
Voltage
Power consumption
Terminal spacing
Terminal
Ambient conditions
WARRANTY CONDITIONS
1. FERRO S.A. company provides a 24-month warranty for a correct operation of the Ferro
pump in agreement with its application and technical conditions specified in the Instruc-
tion Manual, and 6-month warranty for repairs and used spareparts. Warranty period
starts on the final user purchase date. Warranty applies on the territory of Poland, for
other countries seller is responsible for any warranty certificates.
2. The warranty certificate must be completed and stamped by the seller and the installa-
tion company which installed the pump; an incomplete warranty certificate is invalid.
3. The seller is obliged to show the product when selling it; potential later claims regard-
ing surface damage will not be accepted.
4. The customer will make a legitimate claim in the organization where he has bought the
product or directly in the FERRO S.A. company. In case of a claim, he will submit a duly
completed Warranty Certificate together with a purchase receipt ; the claim will not be
accepted unless valid documents are submitted.
5. The warranty covers only flaws provably caused by the manufacturer, not by incorrect
or incompetent installation, a failure to satisfy all instructions specified in the User's
Manual, flaws caused by impurities in the distribution system, freezing, mechanical
damages etc.
6. The warranty does not cover damages caused during transport, unsuitable storage or
improper usage of the product.
7. The warranty does not cover parts that are subject to natural wear caused by standard
application as well as all faults caused by dirts carried by pumped liquid. Usage of prop-
er filter at the pump's inlet is mandatory.
8. The warranty cannot be accepted after any unauthorized interference with the product.

TECHNICAL PARAMETERS

80°C: 0,5 m
CP 15 1.5
0.1 – 0.7 m³/h
1,3 m
min. +2°C, max. +95°C
drinking water
1,0 MPa (10 bar)
90°C: 2 m
IP 42
F
230 V
28 W
85 mm
G 1/2
min. +2°C, max. +40°C
95°C: 3 m