Figure 7. 6500 Series Menu Tree - ADTRAN Express 6500 Series Installation And Maintenance Practice

2-wire/4-wire ltu
Table of Contents

Advertisement

1. LTU
1. Unit Information
2. NTU
Main Menu
1. Unit Options
2. SHDSL Options
2. Provisioning
3. G.703 Options
4. Test Options
1. SHDSL Port
3. Status
2. G.703 Port
3. G.703 Services
4. Reset All Status
1. SHDSL Local Loopback
4. Test
2. SHDSL Remote Loopback
3. SHDSL BERT
4. G.703 Local Loopback
5. G.703 BERT
6. G.703 Services
5. Performance History
1. Restart Bad Splice Detector
6. TSCAN
2. 24 Hour Counts
Local Management
7. Terminal Mode
Remote Virtual Terminal Management
61230011L1-5B
1. Cross-Connect Map
1. Internal Clock
2. Clock Source
2. G.703 Rx Clock
3. Circuit ID
3. SHDSL Rx Clock
4. Date and Time
5. Restore Factory Defaults
6. Upgrade Firmware
1. Disabled
7. Local Management
2. Enabled
8. Change Password
1. Disabled
1. ISDN-PRA V3
2. Enabled
2. G.704 CRC-4 Multiframing
3. Timeslot Idle Pattern
00h to FFh
4. Spare Bits Insertion to Span
00h to FFh
5. Spare Bits Pattern to Span
6. Spare Bits Insertion
00h to FFh
7. Spare Bits Pattern
8. RAI Generation
1. Disabled
9. E-bit Generation
2. Enabled
10. PM Threshold
1. Dual Sided
2. Customer Transparent
3. Customer Non-Transparent
4. Network Transparent
5. Network Non-Transparent
1. Local Loopback
2. Remote Inband Loopback
3. BERT
1. SHDSL Port
2. G.703 Port
3. Reset All

Figure 7. 6500 Series Menu Tree

1. 2-Wire
1. Interface Mode
2. 4-Wire
2. Payload Rate (kbps) *
0. Disabled
3. SNR Margin Alarm Threshold (dB)
1-15. Alarm Threshold
4. Loop Attenuation Alarm Threshold (dB)
1. Disabled
5. Outage Auto-Retrain
2. Enabled
1. ES 15-Minute Alarm Threshold
6. PM Thresholds
2. SES 15-Minute Alarm Threshold
3. UAS 15-Minute Alarm Threshold
1. Disabled
4. CVC 15-Minute Alarm Threshold
2. Enabled
5. LOSWS 15-Minute Alarm Threshold
1. Disabled
2. Enabled
6. OS 15-Minute Alarm Threshold
1. Disabled
2. Enabled
1. Disabled
1. ES 15-Minute Alarm Threshold
2. Enabled
2. SES 15-Minute Alarm Threshold
3. UAS 15-Minute Alarm Threshold
4. CVC 15-Minute Alarm Threshold
1. Loopback Types
2. Inband Loopback Options
3. Loopback Timeout (Min)
4. BERT TX Pattern
5. BERT TX Pattern Polarity
6. Pushbuttons (All)
7. SHDSL Port Select Pushbutton
* 4-wire mode: 192 kbps to 2.304 Mbps (N x 64 kbps, where N=3 to 36)
0. Disabled
1-127. Alarm Threshold
0. Disabled
1-900. Seconds
0. Disabled
1-900. Seconds
0. Disabled
1-900. Seconds
0. Disabled
1-65535. Errors
0. Disabled
1-900. Seconds
0. Disabled
1-900. Seconds
0. Disabled
1-900. Seconds
0. Disabled
1-900. Seconds
0. Disabled
1-900. Seconds
0. Disabled
1-65535. Errors
1. SHDSL Loopback
1. Dual Sided
2. G.703 Loopback
2. Transparent
3. G.703 Services Loopback
3. Nontransparent
1. PN127
1. In-band Loopback Protocol
2. V.54
1. Disabled
2. G.703 Services In-band Pattern Detection
2. Enabled
0. Disabled
1-999. Time out in Minutes
1. ALT
2. 2047
3. 2E15-1
4. QRSS
1. Normal
2. Inverted
1. Disabled
2. Enabled
1. Disabled
2. Enabled
Optioning
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents