3.3 Integrating the Pulse Output from a Power Meter

3.3 Integrating the Pulse Output from a
Power Meter
Prepare a watt-hour meter capable of outputting 50,000
pulses/kWh pulse and capture pulses from the meter to
measure the integrated watt-hour for a one-month (30-
day) period. Observe the integrated watt-hours for a one-
month period by measuring the output pulses of the
watt-hour meter every 30 minutes.
Settings:
Pulse is input to Pulse Channel 1 (P1).
Recording interval: 30 min., Time axis: 1 day, Recording period:
30 days
AC Adapter
Instrument and Accessories Required for Measurement
• Memory HiLogger
• AC adapter
• PC card
• Input cables
• Flat blade screwdriver
• 9641 CONNECTION CABLE
Memory HiLogger
9641 CONNECTION CABLE
Power Meter