Download Print this page

TDE Instruments Digalox DPM72-MPP Instruction Manual

Analogue signal measuring instrument for din rail

Advertisement

Quick Links

Package contents:
1. Safety instructions
• Read instruction manual carefully before operating the device! Keep for later
reference.
• Mounting and installation must be carried out by suitably qualified and competent
persons only.
• When working on the device hazardous voltages must not be connected to
the device! The terminals J1-J12 are not isolated from the measuring
circuit.
• The device must not be used as the only protective device or protective
shutdown.
• The device is not intended to protect persons or facilities against harm. Specific
devices must be used to guarantee safety (protection relays, cut-off switches,
etc.).
• When connecting switches to the terminals J1-J8, only switches must be used
whose isolation voltage is at least twice the maximum occurring measurement
voltage. For example, when measuring 30 V DC switches must be isolated for at
least 60 V.
• Do not open the housing!
• Do not use the device in the presence of explosive or flammable substances!
• All cables carrying hazardous voltages must be secured with external separators.
2. Meaning of symbols
General warning sign
(Attention, observe the documentation!)
Warning of an electrical hazard
®
Digalox
DPM72-MPP/MPPA/MPPV-DIN
Instruction manual (Rev-2021-05)
Analogue signal measuring instrument for DIN rail
Digalox
®
DPM72, 5 jumpers, 2 instruction manuals (EN + DE)
----- 1 / 8 -----

Advertisement

loading

Summary of Contents for TDE Instruments Digalox DPM72-MPP

  • Page 1 ® Digalox DPM72-MPP/MPPA/MPPV-DIN Instruction manual (Rev-2021-05) Analogue signal measuring instrument for DIN rail Package contents: Digalox ® DPM72, 5 jumpers, 2 instruction manuals (EN + DE) 1. Safety instructions • Read instruction manual carefully before operating the device! Keep for later reference.
  • Page 2 3. Intended use • Measurement of current, voltage, power and frequency in the specified measuring ranges. • Indoor use non condensing, non corrosive. • Mounting on DIN rail or screwing on. • Failure to comply with these instructions will void all guarantee and warranty. 4.
  • Page 3 5. Product overview 1 2 optocoupler switch outputs 2 Jumper pins J1–J12 3 Supply voltage input 4 Interface (XBEE / RS485) 5 Measurement inputs 6. Mounting Hook the device into the top-hat rail from above and then press it at the bottom until the latch engages.
  • Page 4: Electrical Connections

    7. Electrical connections WARNING: The device may only be operated in one of the connection options shown! Supply (Digalox) Legend Voltage source, e.g. active sensor 12 - 24 V Fuse 250 mA or sensor with voltage supply Current source, e.g. active sensor −...
  • Page 5 DPM72-MPPA 20 mA analogue signal 2 × 20 mA analogue signal Digalox Digalox high high high high max. max. max. 100 mA 100 mA 100 mA DPM72-MPPV 10 V analogue signal 2 × 10 V analogue signal Digalox Digalox high high high high...
  • Page 6 8. Configuration Connect the device to a computer: USB: Connect the device and the computer using a USB cable. The device driver is installed automatically if the computer is connected to the Internet. XBEE: Insert the XBEE stick into the computer. The device driver is installed automatically if the computer is connected to the Internet.
  • Page 7: Specification

    11. Specification DPM72-MPPA DPM72-MPP DPM72-MPPV 12 - 24 V AC/DC ±10% (50/60 Hz ±10%), Supply galvanically isolated Power consumption Max. 1.2 W ±30 V DC, 20 V AC, Measuring range voltage – 10 - 500 Hz Accuracy voltage – ±0.5 % true RMS Internal resistance voltage –...
  • Page 8 12. Dimensions [mm] 67.5 RS485 57.5 ⌀3.2 61.2 78.7 XBEE 13. Contact information TDE Instruments GmbH, Gewerbestraße 8, D-71144 Steinenbronn Phone: +49 7157 20801 E-mail: info@tde-instruments.de Internet: www.tde-instruments.de, www.digalox.com ----- 8 / 8 -----...

This manual is also suitable for:

Digalox dpm72-mppaDigalox dpm72-mppv-din